(2) Operation panel error

No.
PE 0
• UP position detection error at the time of turning ON the power
PE 1
• Max. zigzag width limitation error
1 When the value of max. zigzag width limitation is changed or zigzag
width of zigzag pattern is larger than max. zigzag width limitation.
2 Zigzag width of the pattern which has been copied from the pattern
copy between panels is larger than max. zigzag width limitation.
PE 2
• Stitch base line position error
1 When the value of max. zigzag width limitation is changed, the zigzag
width is within the value of max. zigzag width limitation. However,
when the zigzag width is out of the area of max. zigzag width limitation
due to the position of stitch base line of the zigzag pattern.
2 Zigzag width of the pattern which
has been copied from the pattern
copy between panels is within max.
zigzag width limitation. However,
when the zigzag width is out of the
area of max. zigzag width limitation
due to the position of stitch base
line.
Description and place to be checked
The sewing machine does not stop
at UP position.
Trouble of synchronizer
Disconnection/looseness of
synchronizer connector
Max. zigzag width limitation
Zigzag width of zigzag pattern
Max. zigzag
width limitation
Position of
stitch base line
77
Corrective measure
• Turn the sewing machine
handwheel by hand and adjust
the marker dot of the sewing
machine.
• Insertion of synchronizer
• Replace synchronizer.
• Make the zigzag width of pattern
smaller than max. zigzag width
limitation.
• Set the position of the stitch
base line within the area of max.
zigzag width limitation.