TECHNICAL SPECIFICATIONS – WELD-PAK 100
Standard Voltage/Frequency
115V/60Hz
115V/60Hz
Duty Cycle
20% Duty Cycle
20% Duty Cycle – CSA Rated Output
Welding Current Range (Continuous) Maximum Open Circuit Voltage
Rated DC Output: 0 - 88 amps
CSA Rated DC Output: 0 - 62 amps
Output Mode
Input Voltage
RATED
115V/60Hz
CSA
115V/60Hz
Height
12.0 in
305 mm

INSTALLATION

INPUT – SINGLE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse or
Breaker Size
20 Amp
15 Amp
PHYSICAL DIMENSIONS
Width
9.75 in
248 mm
Input Current
20 Amps - Rated Output
15 Amps - CSA Rated output
Amps
88
62
OUTPUT
32
Input Amps
Power Cord
20
15 Amp, 125V,
Three Prong Plug
(NEMA Type 5-15P)
12
15 Amp, 125V,
Three Prong Plug
(NEMA Type 5-15P)
Depth
16.5 in
419 mm
Volts at Rated Amperes
18
20
Auxiliary Power
N/A
Extension Cord
Three Conductor
#14 AWG
(2.1 mm
2
) or Larger
Up to 25 Ft. (7.6 mm)
Three Conductor
#12 AWG
2
(3.3 mm
) or Larger
Up to 50 Ft. (15.2 mm)
Weight
47 Ibs
21.4 kg
WELD-PAK 100