12.2.6 OUTPUT TIME SETTING

6.OUTPUT TIME SET
1 Sec
6.OUTPUT TIME SET
- > 0.1 Sec
Output Time Setting Examples
e.g. If you want to activate the Relay#1 (OUT #1) for 3 seconds;
- The Time Unit should be set to "03" for Relay#1 in the menu "1. EXIT".
- Set to 1Sec in the menu 'OUTPUT TIME SET"
e.g. If you want to activate Door Relay#1 (OUT #1) for 0.3 seconds;
- The Time Unit should be set to "03" for Relay#1 in the menu "1. EXIT"
- Set to 0.1Sec in the menu "OUTPUT TIME SET"

12.2.7 ANTI-PASS BACK

7. APB SETUP
DISABLE
7. APB SETUP
- > ENABLE
Anti-Pass Back Setting Menu Items
DISABLE: The Anti-Pass Back feature is disabled.
ENABLE: The Anti-Pass Back feature is enabled.
ALL CLEAR!: All Anti-Pass Back flags are reset, and access will be allowed one time
regardless of the current status of the existing flags.
Output Time Set allows you to define the unit of time.
1 sec: Output Time is calculated in the time unit of 1
second for the In/Output definition.
0.1 sec: Output Time is calculated in the time unit of 1/10
second (or 100ms) for the In/Output definition
To change the setting, press <ENT> and press <4> or <6> to
select the desired time unit and press <ENT> to confirm.
The Anti-Pass Back feature is used to prevent an identical
user from entering or exiting the door more than twice in a
row so that card holders cannot pass back their cards to the
others. Anti-Pass Back can be applied only when an Exit
Reader is installed. To enable or disable Anti-Pass Back or to
reset all APB flags, press <ENT> and press <4> or <6> to
select the desired item and press <ENT> to confirm.