12.1.1. TIME SETTING

1. TIME SETTING
MM/DD hh:mm:ss
YYYYMMDDhhmmssW

12.1.2. COMMUNICATION ADDRESS

2. COMM ADDRESS
00

12.1.3. BAUD RATE

3. BAUD RATE
9600
3. BAUD RATE
->19200
The LCD displays the current time. To change the time, press
<ENT>, enter 15 Digits in a "YYYYMMDDhmmssW" format,
and then enter <ENT> again to confirm.
NOTE: For the days of the week (W),
1 : Sun, 2 : Mon, 3 : Tue, 4 : Wed, 5 : Thu, 6 : Fri, 7 : Sat.
e.g: To input October 12, 2009, 13:30:15, Monday, enter
200910121330152.
A communication address is a unique number assigned to
each device for communication. The default address is 00.
For proper communication with the PC, it is important that the
value you set here should match the value you set on the
application software. It is also important to make sure each
device on a loop has a unique address.
To
change
the
FINGER007SRB, press <ENT>, enter the desired 2-Digit
address in the 00-31 range, and then press <ENT> again to
confirm.
Baud Rate is the measurement of the serial communication
speed. As with the communication address, the baud rate you
set here should match the value you set on the software.
Baud Rates of 4800bps, 9600bps, 19200bps, 38400bps,
57600bps and 115200bps are supported, and 9600bps is
default.
To change the Baud Rate, press <ENT>, select the desired
baud rate by pressing <4> or <6>, and then press <ENT>
again to confirm.
NOTE: If a TCP/IP module is being used, the Baud Rate
setting must be set the same as the TCP/IP module
setting.