11. OPERATION

11.1 NORMAL OPERATION

Power On
When the power is applied to FINGER007SRB, the "RED LED" is turned on.
Registered Card Reading
When a registered card (or PIN) is read, the door (Relay1) will open for 3 seconds(Defaults) with the
"GREEN LED" on.
Exit Button
To exit from inside, an Exit Button (Or External Reader) can be used.
The Door (Relay1) is opened for 3 seconds (Defaults) with the LED on.
Alarms (Unregistered Card/ Password / Time Schedule / Door Error)
When an unregistered card is read, wrong password is input, over the Time Schedule, and access
wrong door, the access is denied and the alarm (Relay 2) is activated for 3 seconds (Defaults) with
"RED LED" on.

11.2 DEFAULT SETTING

When you operate the FINGER007SRB first time or you initialize the FINGER007SRB, the
controller will set up all values to default settings (Factory Settings). You can change the
settings for desired application. Please refer to the "APPENDIX" (54p) section at the back of
this manual for the default setting values.