Serial Interface; Sio Pass Through Scheme; Sio (Rs232) Control Setting Procedure - Imi Tech PEARL IMB-20FT User's Operation Manual

Pearl series firewire ccd & cmos cameras
Table of Contents

Advertisement

PEARL SERIES Operation Manual
5.8.

Serial Interface

The Pearl Series cameras are equipped with the SIO (Serial input/output) feature described in the IIDC 1.31
specification. By using the serial interface, the user can execute commands by writing data in a specific address in
the FireWire address range. SIO can be further used as an RS232 interface which supports pass through and IMI
tech commands.
5.8.1.

SIO Pass Through Scheme

SIO(RS232) Pass Through
5.8.2.

SIO (RS232) Control Setting Procedure

STEP 1. Configuration of Registers Address : F2F22000h
Baud Rate : 9600, No Parity, 1 bit Stop, 8 bit data length
Write : F2F22000h, Data = 050800000h
Value read after write = 050800020h 20 is the buffer of TX and RX
STEP 2. Enable RS232 TX / RX Address : F2F22004h
Write Data : C00000000 : Now RS232 TX / RX port is enabled
P i o n e e r i n D i g i t a l V i s i o n T e c h n o l o g y
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
SECONDS COUNT
CYCLE COUNT
Bit Numbe r
Bit Nam e
0 - 6
SECONDS COUNT
Seconds Coun t
7 - 19
CYCLE COUNT
Cycle Coun t
20 - 31
CYCLE OFFSET
Cycle O ffset
FIREWIRE
Cable
CYCLE OFFSET
Function
DIR
Description
R/W
1 Hz c ycle timer counte r
R/W
8,000 Hz c ycle timer counte r
R/W
24.576 MHz c ycle timer counte r
User Target System
System
Controller
Camera