Trigger Mode 3; Trigger Mode 4 - Imi Tech PEARL IMB-20FT User's Operation Manual

Pearl series firewire ccd & cmos cameras
Table of Contents

Advertisement

PEARL SERIES Operation Manual
4.9.8.

Trigger Mode 3

Not supported at Format 7 Mode
This is an internal trigger mode.
(parameter) the cycle time of the fastest frame rate. The Integration time of the incoming light is described in the
"Shutter" register. A Parameter is required and shall be one or more (N>=1)
4.9.9.

Trigger Mode 4

This mode is the "multiple shutter preset mode". The Camera starts the integration of the incoming light from the
first external trigger input falling edge and exposes the incoming light at shutter time. Repeat this sequence for
the N-th (parameter) external trigger input falling edge and then finish integration. A parameter is required and
shall be one or more. (N >= 1)
P i o n e e r i n D i g i t a l V i s i o n T e c h n o l o g y
The Camera will issue a trigger internally and the cycle time is N times
Page 51