Strobe Delay and Duration Table

The table shows the strobe index by the increment step through strobe delay time and strobe duration time.
Increment Step is different according to strobe index.
Strobe Index(Y)
0
1
2
3~250
251~489
Strobe Delay/Duration Index

4.12. Optical Filter Control

The Optical Filter control allows the user to change the optical filter of the camera. You can change the Bayer
pattern by moving the starting position of the pattern by one position up, down, right or left. (Only for color
models)
Abs_Control
-
On/OFF
-
Value
Strobe Delay/Duration Table
Increment Step
1us
250us
T=(Y-250)*250us+250us
0
1
2
10
100
250
253
257
269
289
329
449
489
[1]
Absolute value control
0: Control with value in Value field
1: Control with value in Absolute value
CSR if this bit =1, value in Value filed is
ignored
[2..5]
Reserved
[6]
Write : ON or OFF this feature
Read : read a status
0: OFF,
If this bit=0, other fields will be read only.
[7..19]
Reserved
[20..31]
Minimum value for this feature control
Strobe Delay Time : T
Delay Time
Duration Time
0us
1us
2us
T=Y us
T=(Y-250)*250us+250us
Strobe Delay Time
0us
1us
2us
10us
100us
250us
1ms
2ms
5ms
10ms
20ms
50ms
60ms
P i o n e e r i n D i g i t a l V i s i o n T e c h n o l o g y
PEARL SERIES Operation Manual
1: ON
Range
N.A
N.A
2us
T=Y us
3us~250us
500us~60ms
Strobe Duration Time
N.A
N.A
2us
10us
100us
250us
1ms
2ms
5ms
10ms
20ms
50ms
60ms