Power Supply; Electrical Specifications; Adjust Door; Checking Door Alignment - U-Line U-ADA15IMB-00 Install Manual

Icemaker series
Hide thumbs Also See for U-ADA15IMB-00:
Table of Contents

Advertisement

9

9 Adjust Door

Checking Door Alignment

The unit's door is aligned at the factory before shipment. However,
its alignment could have been disturbed during shipment.
IMPORTANT
IMPORTANT
Properly aligned, the door's gasket should be firmly in
contact with the cabinet all the way around the door (no
gaps).
1. Carefully examine the door's gasket to assure that it is firmly in
contact with the cabinet.
2. When inspecting door alignment, make sure the door gasket is
not pinched on the hinge side of the door.

Adjusting Door Alignment

BI-2115
1. Remove top hinge screw pin Remove door by tilting forward
and lifting off bottom hinge pin.
2. With door upside-down, loosen but do not remove the two
screws on the door's bottom hinge plate.
3. If the top far edge of the door
needs to move UP, move the
hinge plate toward the outside
of the door and retighten
screws. If the top far edge of
the door needs to move
DOWN, move the hinge plate
toward the inside of the door
and retighten screws.
4. Mount the door to recheck
alignment and repeat Steps 2
and 3 if further adjustment is
necessary.
5. When top edge of door is
parallel to top edge of cabinet,
remove the door and ensure
the two screws are secure.
6. Remove the door closers
from the bottom hinge, clean
thoroughly and lubricate the mating surfaces with petroleum
jelly.
7. Reinstall the closers, lining up the bosses with holes in hinge and
hinge plate.
8. Mount the door, install top hinge pivot pin
All Other Models
1. Loosen (do not remove) top and bottom hinge screws.
2. Align door squarely with cabinet. Make sure gasket is firmly in
contact with cabinet all the way around the door (no gaps).
3. Tighten bottom hinge screws.
4. Tighten top hinge screws.
Slotted
Mounting
Notch
Holes
(must face toward
center of door)
Raise
Lower
Outside
Outside
Door Edge
Door Edge
Door
Closer
Inserts
Boss
U-Line Other Requirements

10 Power Supply

Electrical Specifications

WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from the
plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the
unit.
IMPORTANT
IMPORTANT
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.
ADA15IM
23-1/8"
7"
1-1/2"
BI95, WH95TP, BI95BTP & BCM95
18-1/2"
Minimum
7"
1-1/2"
BI98
21-1/2"
Minimum
7"
4"
SP18
26-5/16" Minimum
7"
1-1/2"
SS-1095(NF)(FC)(FD)
Preferred
Location
Acceptable
for Receptacle
Location
7"
1-1/2"
BI2115
24"
7"
1"
13