Door Swing Dimensions

All units have a zero clearance for the door to open 90°. U-Line
recommends a minimum door clearance of 2" to accommodate
the handle if the unit is installed next to a wall or similar type of
structure.
ADA15IM Series
Wall
1/4" Min.
20-7/8"
16-1/2"
Ü
Door Swing
(Without Handle)
BI98
Wall
1/4" Min.
17-3/8"
16-1/2"
90°
Door Swing
SS1095NF
Wall
1/4" Min.
14-3/8"
15-1/2"
90°
Door Swing
Wall
2" Min.
20-7/8"
16-1/2"
Ü
Door Swing
(With Handle)
SP18
Wall
3/4" Min.
22"
15-1/8"
15-1/2"
90°
Door Swing
SS1095FC/FD
WH95, BI95BTP, BCM95
Wall
3/4" Min.
14-3/8"
15-1/2"
90°
Door Swing

Other Site Requirements

6 Other Site Requirements

Power Supply

Units requires a grounded and polarized 115 VAC, 60 Hz, 15A
circuit (normal household current). See Electrical Specifications on
Page 14.

Water Supply

Units require a 1/4" OD water supply line and a shut off valve. For
more information see page 15

Environmental Requirements

Units are designed to operate between 50°F (10°C) and 100°F
(37°C). High ambient temperatures (100°F [37°C] or higher) may
reduce the unit's ability to reach low temperatures and may also
reduce the ice production rate for those models with ice makers.
If the ambient temperature is expected to drop below 45°F (7°C),
drain all water from the unit to prevent freezing damage, which is
not covered by the warranty.
For best performance, keep the unit out of direct sunlight and away
from heat generating equipment.
For best performance and life outdoors, place under a counter or
provide shelter of some kind.
In climates where high humidity and dew points are present,
condensation may appear on outside surfaces. This is considered
normal. The condensation will evaporate when the humidity drops.
.