Aligning the PTP 600 Series Bridge ODUs
The PTP 600 Series Bridge uses audible tones during installation to assist the installer with
alignment. The installer should adjust the alignment of the ODU in both azimuth and elevation until
highest pitch tone is achieved
The pitch of the alignment tone is proportional to the received power of the wireless signals. The
best results are usually achieved by making small incremental movement in angular alignment.
The tones and their meanings are as follows:
State Name
Free Channel
Search
Scanning
Synchronized
Registered
The term 'wanted signal' refers to that of the peer unit being installed.
In each of the states detailed above, the unit should be aligned to give the highest pitch tone. It
should be noted that if, when in the Synchronized or Registered state, the tone varies wildly, you
may be suffering from interference or a fast fading link. Installing in this situation may not give a
reliable link. The cause of the problem should be investigated.
For the ease of alignment, both Master and Slave units use the install tones in the same way but
with some small behavioral differences. This allows the installer to install the Slave unit first and
carry out the initial alignment with the Master unit if desired. However, due to the behavioral
differences of Master and Slave units, it is recommended that the Master unit is installed first and
the initial alignment carried out at the Slave unit.
Once the optimum performance has been achieved by directing the Slave unit (indicated by
highest frequency of tone) then adjustment of the direction of the Master unit should be done
without moving the Slave. Repeat if necessary at the Slave and then the Master until optimum
alignment has been obtained.
More information:
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299

Installation and Commissioning

.
Tone
Description
Regular beep
Slow broken tone
Fast broken tone
Solid tone
PTP 600 Series User Guide
State
Description
Executing band
scan
Not demodulating
the wanted signal
Demodulating the
wanted signal
Both Master and
Slave units
exchanging Radio
layer MAC
management
messages
Section:
"Establishing a Radio Link"
19
Pitch Indication (Higher
pitch = higher power)
N/A
Rx Power
Rx Power
Rx Power