Motorola PTP 600 Series Installation Wiring
Cable to LPU & ODU
grounding by means
of the grounding
glands provided
Cable to LPU
grounding by means
of the grounding
glands provided
Ethernet
Cabling
to T-568B
Inside Building
More information:
PTP 600 Series User Guide
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299

Installation Wiring

PTP 58600 ODU
+55V and
LED/Reset
Signalling
Ethernet
Ethernet
Ethernet
P8
P7
P5
P4
P6
P3
8
7
5
4
6
3
P7
P5
P4
P6
P3
P8
8
7
5
4
6
3
Ethernet
Ethernet
Ethernet
+55V and
LED/Reset
Signalling
All upper tower
grounds should be
within 0.3 metres of the
0V
ODU bracket and on
the same metal
Ethernet
Chassis
RJ45
RJ45
PTP LPU
Grounding
P2 P1
cables provided
RJ45
2
1
There may be a local regulatory
requirement to cross bond the
CAT 5e cable to the mast at
intervals as regular as every 10
metres. This can be achieved
using an Andrew grounding
assembly type 223158 or
similar.
RJ45
PTP LPU
P2 P1
RJ45
2
1
RJ45
Figure 1 Motorola PTP 600
PIDU
Series Simplified Circuit and
Plus
Ethernet
0V
Section:
"Lightning Protection"
11
Grounding requirements