EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Connector
Spring
Cassette Pin
8. Remove the spring from the main unit and the Cassette Pin.
9. Slide the Cassette Pin to remove it.
When attaching the spring, first hitch its one end to the main frame, and then hitch the
other end to the Cassette Pin.
10.Slightly lift the HVPS Unit to disconnect the two connectors, and then remove the HVPS
Unit.
11.Remove the Cassette Pin Holder.
DISASSEMBLY AND ASSEMBLY
Cassette Pin Holder
Main Unit Disassembly/Reassembly
OK
Springs
The grounding plate end should come above the HVPS Unit.
Make sure the Contact Pin is properly positioned.
The contact points on the HVPS Unit should properly contact with the springs.
Revision B
NG
Grounding Plate
Contact Pin
80