Extra; Receiver; Battery Management; Cue Function - AKG IVM4500 IEM User Instructions

Hide thumbs Also See for IVM4500 IEM:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
To activate the bypass, select "ON". All SOUND Settings will be deactivated.
To deactivate the bypass, select "OFF". The SOUND Settings will be activated.
The EXTRA menu provides six submenus that appear in the following order:
You can choose from the following modes:
- "STEREO" for stereo input signals.
- "DUAL" for two independent input signals.
- "MONO" for mono input signals.
- "SR4500" for mono transmission to an SR 4500 receiver.
In DUAL and SR4500 modes, no room simulation is available and the com-
pressor will operate on channel 1 only.
Mono signals will not be transmitted in mono unless the room simulator is de-
activated.
You can choose from the following modes:
- "AUTO": When the transmitter is in SETUP mode and nobody touches a con-
trol for approx. three minutes, the transmitter will automatically switch to
LOCK mode. (You can still switch to LOCK mode manually at any time.)
- "MANUAL": You can only lock the setup menus manually.
You can set the brightness of the display from 1 (dark) to 10 (bright).
This setting is only active in LOCK mode.
You can call up the following details about your transmitter in this order:
- Firmware version (e.g., "F 3.09")
- Frequency band (e.g., "B 5.E5")
- Preset version (e.g., "P 1.00")
- Audio preset version (e.g., "A 03.00")
You can reset all parameters to their default settings ("YES") or leave them un-
touched ("NO").
Press SETUP briefly. The display will revert to the EXTRA screen.
In addition to the basic functions described in section 3 above, the SPR 4500 re-
ceiver provides a number of advanced functions.
To make sure the receiover battery capacity is indicated correctly:
Do not use any dry or rechargeable batteries other than the types listed below.
Never use batteries that have been in use during the previous 24 hours.
Match the receiver system to the type of battery you inserted:
1. Select the "BAT" menu.
2. Use the jog switch to select the desired setting:
"Lr6" for AA size (LR6) alkaline dry batteries. The display indicates the remain-
ing battery capacity as a bar graph.
"Fr6" for AA size (FR6) lithium batteries. The display indicates the remaining
battery capacity as a bar graph.
Lithium batteries have a life of up to 10 hours. With new lithium batteries, the
display will constantly indicate four rectangles during initial operating hours.
"Hr6" for AA size (HR6) NiMH rechargeable batteries. If the battery capacity
drops below 20% the display will show the "LO.BAT" warning.
• The optional BP 4000 battery pack is detected and indicated automatically.
The "CUE" function allows you to listen to each of up to 16 monitor channels. You
can select the appropriate frequencies and save them as a GROUP. In LOCK mode,
you can use the jog switch to scroll through these frequencies. You can only add,
delete, or modify CUE frequencies when the CUE function is active.
1. In SETUP mode, turn the jog switch CW or CCW a s many times as required to
display "CuE.ON", and press the jog switch briefly.
4 Advanced Functions
IVM
4500
BYPASS:

EXTRA

MODE:
Note:
LOCK:
LIGHT:
INFO:
RESET:
ESCAPE:

Receiver

Battery Management

CUE Function

Activating/
Deactivating CUE
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sst 4500Spr 4500

Table of Contents