Test Engineering - LifeFitness 95T ELEVATION SERIES Service Manual

95t elevation series treadmills
Hide thumbs Also See for 95T ELEVATION SERIES:
Table of Contents

Advertisement

Appendix
Engage / Inspire Console Diagnostic:
User Interface
Object Table
LABEL
Phase Test Readouts
Start Test Button
Back Button
Main Menu Button
DESCRIPTION
NULL Report: Checks the balance of the phases. This value should be <=3 (0.3a).
Phase U/W/V Low/High: Checks the individual phases and transistors. These values
should be in the 30's (~3a-4a). If one phase pair (Low/High) shows very low, the
cable/connector or motor needs to be checked. If individual phase(s) are substantially
different, the DSP board needs to be checked.
Runs the test engineering phase test.
Goes back to the previous screen.
Goes back to the System Options – Main Menu.

Test Engineering