KitchenAid KESS300B Reference Manual page 36

Electronic range controls “b” & “d” line wall ovens
Hide thumbs Also See for KESS300B:
Table of Contents

Advertisement

COMPONENT
ILLUSTRATION
ELEMENT
TERMINALS
SENSOR TERMINALS
TERMINAL
TERMINAL
CONVECTION
FAN MOTOR
COOLING
FAN MOTOR
TERMINALS
Test Chart 2
COMPONENT
Coil Elements
Ceran Elements
Convection Fan Motor
Cooling Fan Motor
- 32 -
TEST PROCEDURE
Set the ohmmeter to
R x 1.
Connect the meter leads
to the element termi-
nals, and measure the
continuity.
Set the ohmmeter to
R x 1.
Connect the meter leads
to the element terminals,
and measure the conti-
nuity. NOTE: Halogen
tubes should show conti-
nuity.
Set the ohmmeter to
R x 1.
Connect one of the
meter leads to circuit
board pin J1-1.
Connect the other meter
lead to circuit board pin
J1-6.
Set the ohmmeter to
R x 10.
Connect one of the
meter leads to circuit
board pin J1-1.
Connect the other meter
lead to the yellow wire
marked "FAN" on the
cooling fan thermal
switch.
TEST RESULTS
8 " Coil (2600W) =
22 Ω ±5 Ω
6 " Coil (1500W) =
38 Ω ±5 Ω
9 " Rad (2400W) =
22 Ω ±5 Ω
7 " Rad (1700W) =
32 Ω ±5 Ω
6 " Rad (1400W) =
39 Ω ±5 Ω
7 " Hal (1800W) = 0 Ω
Dual Oval (2500W Tot)
Hal Inner (1500W) = 0 Ω
Rad Outer (1000W) =
50 ±5 Ω
15 Ω. ±3 Ω
65 Ω. ±10 Ω

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents