5.OUTDOOR UNIT
Heating peak capacity and power input
Capacity (kW)
-20
-15
-7
-2
2
TO
(°C)
7
10
12
15
20
Power input (kW)
-20
-15
-7
-2
2
TO
(°C)
7
10
12
15
20
COP
-20
-15
-7
-2
2
TO
(°C)
7
10
12
15
20
* Heating capacity and power input are shown peak value during operation.
* Heating capacity and power input are shown at maximum compressor operating requency
* Power input does not include water pump power.
TO
:
Outdoor temperature (DB°C) RH85%
LWT
:
Leaving water temperature (°C)
30
35
6.69
6.41
7.97
7.64
10.38
9.96
11.85
11.38
13.02
12.52
15.41
14.82
16.46
15.82
17.15
16.49
18.11
17.41
20.27
19.49
30
35
2.31
2.48
2.66
2.86
2.85
3.07
2.91
3.14
2.96
3.19
3.01
3.24
3.01
3.23
3.00
3.23
3.01
3.24
3.04
3.27
30
35
2.90
2.59
2.99
2.67
3.64
3.24
4.07
3.63
4.41
3.92
5.12
4.57
5.47
4.89
5.71
5.11
6.01
5.37
6.67
5.96
LWT (°C)
40
45
6.21
6.03
7.40
7.19
9.65
9.38
11.05
10.75
12.16
11.85
14.47
14.16
15.42
15.08
16.06
15.69
17.19
17.02
19.25
19.07
LWT (°C)
40
45
2.68
2.88
3.10
3.33
3.33
3.57
3.41
3.67
3.47
3.74
3.56
3.88
3.57
3.91
3.57
3.92
3.60
3.97
3.64
4.02
LWT (°C)
40
45
2.31
2.09
2.38
2.16
2.90
2.62
3.24
2.93
3.51
3.17
4.06
3.65
4.32
3.86
4.49
4.00
4.77
4.29
5.29
4.75
43
Engineering Data book
50
55
—
—
—
—
9.10
—
10.43
9.64
11.49
10.62
13.81
12.82
14.96
14.14
15.58
14.87
16.62
15.76
18.81
17.67
50
55
—
—
—
—
3.86
—
3.96
4.20
4.04
4.29
4.22
4.52
4.27
4.59
4.30
4.64
4.36
4.72
4.43
4.80
50
55
—
—
—
—
2.36
—
2.64
2.29
2.85
2.48
3.27
2.84
3.51
3.08
3.62
3.21
3.81
3.34
4.25
3.68