4.HYDRO UNIT

4-4. Wiring Diagram

4-4-1. Hydro unit
Color identification
BLU : BLUE
BLK : BLACK
BRW : BROWN
GRN : GREEN
GRY : GRAY
ORN : ORANGE
PNK : PINK
RED : RED
WHI : WHITE
YEL : YELLOW
CN10
(WHI)
YEL
9
9
CR10
RY
8
10
BLU
7
7
CR11
RY
6
11
BRW
5
5
CR12
4
3
CR13
2
WHI
1 1
CN01
(WHI)
WHI
3
3
2
RED
1 1
F01 (5A)
WHI WHI
1
2
3
4
5
6
7
8
9
1
2
3
4
TB 05
5
5
5
5
5
5
5
5
5
4
4
4
4
WPM
2WV
BH
3WV
MIXV
Type 1
(2-wire spring return)
(3-wire SPDT type)
7
8
9
1
2
3
4
TB 05
5
5
5
4
4
4
4
*See DIP SW13_1
3WV
MIXV
Type 2
(3-wire SPST type)
(3-wire SPST type)
Type 3
(3-wire SPDT type)
1
2
3
TB 01
1
1
1
1 2
3
Outdoor unit
Power supply
220 - 230V~ 50Hz
1L1
3L2
or
1L1
RY05
380 - 400V~ 50Hz
2T1
4T2
2T1
F1, F2
Fuse
F1 F2
AC250V
F3 F4
T30A
*Option
TB 03
1 2
L
N
3
3
1 2
Power supply
220 - 230V~ 50Hz
380 - 400V 3N~ 50Hz
Hot water cylinder
Symbol
WPM
Water pump motor
3WV
3-way valve (locally procured)
2WV
2-way valve (locally procured)
MIXV
Mixing valve (locally procured)
BH
Booster heater
RY01~RY06
Relay01~Relay06
LPS
Low pressure sensor
Backup heater1, 2, 3
Heater AC230V, 3kW
1. The one-dot chain line indicates wiring at the local site, and the dashed line indicates accessories sold separately and service wires,
respectively.
2.
, and
indicates the terminal board and the numberals indicate the terminal numbers.
3.
indicates P.C. board.
* Be sure to fix the electric parts cover surely with screws. (Otherwise water enters into the box resulting in malfunction.)
*Option
Remote
controller
(HWS-AMS11E)
TC
TWI
Remote
A B
controller
(HWS-AMS11E)
A B
A
B
TB 07
7
7
1 2
1 2
3
1 2
3
1
1
1
2 3
1 2
1
2 3
CN41
CN203
CN204
(BLU)
(YEL)
(BRW)
6
RED
5
5
BLU
5 5
4
4
CN501
RY
ORN
4
4
3
3
(YEL)
12
CN02
GRN
3
3
2
2
(WHI)
RY
BRW
2
2
1
1
13
1 1
1
Relay
p.c.board
(MCC-1431)
BLK
SW01
BLU
SW02
3
3
CN603
WPM
N N
(YEL)
BRW
ON
L
L
1
1
1 2
RED
3
3
CN601
(RED)
RY
WHI
A2
A1
1
1
05
ON
YEL
7
7
WHI
5
5
3
RED
1
1
CN602
(WHI)
TB 04
RY604
RY605
Type 1
CN604
CN605
(BLU)
(YEL)
7
5
3
1
7
5
3
1
TB 04
5
7
RY
01
RY
06
Type 2
2
4
6
8
PNK
ORN
Thermal protector
Backup heater 1
(Single operation)
95 5
Thermal protector
Backup heater 2
(Single operation)
95 5
Backup heater 3
Thermal protector
(Single operation)95 5
3L2
5L3
1
L
1
3
L
2
5L3
1
L
1
3
L
2
5
RY02
RY04
4T2
6T3
2T1 4T2
6T3
2T1
4T2
6T3
GRY
F5
F6
F7
F8
F3
F4
F5
F3~8
Fuse
AC250V
T30A
L1 L2 L3 N
TB 02
L
HWS-803XWHT9-E
Power supply
Power supply
380 - 400V 3N~ 50Hz
HWS-1403XWHT9-E
Parts name
TWO
THO
*Option
LPS
TTW
TFI
1
2
3
4
2
3 4
A B
2
3
4
2 3 4
A
B
C
D
TB 06
6
6
6
6
1 2
3
1 2
3
1
1
2
2
1
1
2
1
2
3
1
2
1
2
3 4
1 2
1
2
3
CN205
CN206
CN207
CN212
CN214
CN213
1
1
(RED)
(WHI)
(BLU)
(WHI)
(WHI)
(WHI)
CN208
2
2
(BLU)
3
3
4
4
1
1
P.C.board
CN209
2
2
(MCC-1511)
(GRN)
3
3
4
4
1
1
CN210
2
2
(RED)
3
3
4
4
SW14
1
1
CN211
2
2
(BLK)
3
3
4
4
3
4
1
1
CN200
2
2
(RED)
SW10
SW 11 SW12
SW13
3 3
CN201
ON
ON
ON
1 1
(WHI)
2 2
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 1
CN202
SW06
2
(YEL)
3
3
ON
SW07
1
1
1
2
2
2
CN102
3
3
(WHI)
4
4
5
5
6
6
RY606
RY607
CN101
(WHI)
1 1
3 3
F100
Fuse
P100 BLK
CN606
CN305
CN100
T5A
(BLU)
(GRN)
(WHI)
250V~
1
3
1
3
3
1
5
3
1
1
3
1
3
3
3
1
*
1 HWS-803XWHT6-E : Installed
6
A2
8
6
A1
HWS-1403XWHT6-E : Installed
RY
RY
RY
HWS-803XWHD6-E : Installed
02
03
04
HWS-1403XWHD6-E : Installed
4
A1
7
4
A2
HWS-803XWHT9-E : Installed
WHI
WHI
HWS-1403XWHT9-E : Installed
HWS-803XWHM3-E : Not installed
*
1
HWS-1403XWHM3-E : Not installed
Thermal protector
Backup heater 1
Thermal protector
(Single operation)
(Single operation)
95 5
95 5
Thermal protector
Backup heater 2
(Single operation)
95 5
RY02
L
3
1L1 3L2
5L3
1L1 3L2
5L3
RY02
RY04
2T1 4T2
6T3
2T1 4T2
6T3
BLK
F6
F3
F4
F3~6
F3,F4
Fuse
Fuse
AC250V
AC250V
T30A
T30A
1
L L3 N
2
TB 02
L
N
TB 02
Power supply
HWS-803XWHT6-E
220 - 230V~ 50Hz
HWS-1403XWHT6-E
Symbol
TC
Water heat exchanger temperature sensor
TWI
Water inlet temperature sensor
TWO
Water outlet temperature sensor
THO
Heater outlet temperature sensor
TTW
Hot water cylinder temperature sensor
TFI
Floor heating inlet temperature sensor
TB
Terminal block
20
Engineering Data book
*Option p.c.board
GRN
4
1
1
K1
Boiler control O/P
GRN
Relay
3
2
2
p.c.board
GRN
2
3
3
Alerm O/P
(MCC-1217)
K2
GRN
1
4
4
PJ20
TB1
GRN
4
Compressor operation
1
1
K1
GRN
Relay
3
O/P
2
2
p.c.board
GRN
2
3
3
K2
Defrost O/P
(MCC-1217)
GRN
1
4
4
PJ20
TB1
YEL
1
1
YEL
Photocoupler input
3
2
2
p.c.board
YEL
2
Emergency stop I/P
3
3
(MCC-1214)
YEL
1
4
4
PJ17
TB1
YEL
1
1
YEL
Photocoupler input
3
2
2
p.c.board
YEL
2
Cooling thermostat I/P
3
3
(MCC-1214)
YEL
1
Heating thermostat I/P
4
4
PJ17
TB1
YEL
RY
7
8
2 2
01
GRN
Flow switch
1 1
RED
BLK
1 1
Pressure switch
BLK
4.15MPa
3
3
BLK
Thermal protector
BLK
(auto) 75 5
BRW
BRW
RED
RED
ORN
ORN
Transformer
WHI
WHI
Backup heater 1
Thermal protector
(Single operation)
95 5
Thermal protector
(Single operation)
95 5
RY02
1
L
1
3
L
2
5
L
3
1L1 3L2
5L3
RY04
2T1
4T2
6T3
2T1 4T2
6T3
BLK
F3
F4
F5
F6
F3~6
Fuse
AC250V
T30A
L
1
L
2
L3
TB 02
Power supply
HWS-803XWHM3-E
HWS-803XWHD6-E
220 - 230V 3~ 50Hz
HWS-1403XWHM3-E
HWS-1403XWHD6-E
Parts name
4
Backup heater 1
Backup heater 2