11. Auto White Balance 5800K Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Adjustment Page
F
Adjustment Address
88 to 8F, A0 to A3, B1, B3
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 5800K Standard Data Input" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
4
6
2C
01
5
6
90
00
6
6
91
04
7
6
92
00
8
6
93
00
9
6
01
79
10
6
07
11
6
01
00
12
F
A0
29
13
F
A1
98
14
F
A2
61
15
F
A3
08
16
6
B6
03
17
6
37
08
18
6
01
A5
19
6
02
20
6
01
00
21
6
37
07
22
6
01
C3
23
6
02
Note 2: The adjustment data will be automatically input to page:
F, address: 88 to 8F, A0 to A3, B1 and B3.
Procedure
Place the C14 filter on the
lens.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting". (Refer to page 5-14)
Press PAUSE button.
Check the data changes to
"01".
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
(Note 2)
Check the data changes to
"01".
Press PAUSE button.
Press PAUSE button.
(Note 2)
Check the data changes to
"01".
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
37
3
6
B6
4
6
2C
5
6
91
6
7
5-23
DSC-P71/P71M
Procedure
00
Press PAUSE button.
00
00
00
00
Release the data setting
performed at step 2.
(Refer to page 5-13)
Remove the C14 filter on the
lens.