Fuser Solenoid Service Check - Lexmark T63x Service Manual

4060-xxx (including 4060-000, 4060-010, 4060-200, 4060-210, 4060-400, 4060-410)
Hide thumbs Also See for T63x:
Table of Contents

Advertisement

Fuser solenoid service check

CAUTION: There is a danger from hazardous voltage in the area of the printer where you
are working. Unplug the printer before you begin, or use caution if the printer must receive
power in order to perform the task.
Service tip: Try changing the envelope enhance level setting. A different setting may correct the
problem.
Note: Check the fuser envelope conditioner solenoid adjustment as described in the adjustment
section
"Fuser solenoid adjustment" on page
FRU
1
Fuser envelope conditioner
solenoid
2
System board
3
LVPS
4
Fuser board to system
board cable
5
Fuser assembly
4-2.
Action
Observe the operation of the fuser solenoid by removing the redrive
assembly. Check for proper mechanical operation of the solenoid
and associated hardware, link, and so on. If correct, check the
resistance of the solenoid between J4-1 and J4-2 on the fuser control
board. The resistance measures between 5 ohms and 10 ohms. If
1
J2
1
J1
incorrect, replace the fuser assembly. If correct, go to step 2.
Measure the voltage at the +42 V dc test point on the system board.
The voltage should measure approximately +42 V dc. If incorrect, go
to step 3. If incorrect, go to step 4.
Measure the voltage at CN2-18 on the LVPS. The voltage should
measure approximately +42 V dc. If incorrect, replace the LVPS
assembly. If correct, replace the system board. If this does not fix the
problem, replace the interconnect board assembly.
Make sure the cable is connected properly to the system board and
fuser control board. Reconnect the cable, if necessary. If the cable is
connected correctly, go to step 5.
If no problems were found in steps 1 through 4, replace the fuser
assembly. See
"Fuser assembly removal" on page
4060-xxx
1
J4
1
J5
1
J6
4-23.
Diagnostic information
2-55

Advertisement

Table of Contents
loading

This manual is also suitable for:

T630T632T634T63 series