Vent Guidelines - Jøtul GI 550 DV Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Hide thumbs Also See for GI 550 DV:
Table of Contents

Advertisement

Mantel Clearance Requirements
MANTEL
AREA
3.5”
5.5”
7.5”
9.5”
11.5”
A
B
C
D
E
Figure 5. Minimum Mantel Clearances shown
measured from the hearth surface to the mantel
surface.
Surround
A
B
Type
Jøtul
48"
46 1/2"
Cast Iron
Jøtul
50"
48 1/2"
Cast Iron
w/ Plinth
Steel
50"
48 1/2"
Double
Doors
Scan 70i
50"
48 1/2"
w/ Mantel
Heat Shield
51"
49 1/2"
Scan 70i
Use noncombustible
without
Mantel
Heat Shield
Table 2. Mantel clearances.
C
D
E
45"
43 1/2"
42"
47"
45 1/2"
44"
47"
45 1/2"
44"
With 1" Riser
47"
45 1/2"
44"
With 2" Riser
48"
46 1/2"
45"
materials only.

Vent Guidelines

• All vent components must be installed in accor-
dance with the listing terms and manufacturer's
instructions.
• Vent Height: Measured from the top of the insert
to the top of the termination cap.
Minimum: no less than 10'
Maximum: no greater than 35'.
The minimum vent height above the roof or
adjacent walls is specified by building codes. As a
general guide, follow the Gas Vent Rule on page 12.
• HORIZONTAL RUNS ARE NOT PERMITTED ANY-
WHERE IN THE VENTING SYSTEM.
• Venting liners used on this appliance may not be
less than 3" in diameter or greater than 3" in diam-
eter.
• Any unused flue or masonry enclosure can be used
as a passageway for venting provided the flue is
relined using 3" Listed flexible gas liner.
• The remaining space around the liner in a masonry
or zero-clearance flue CANNOT be used to vent any
other appliance.
• Flexible liner components may not be exposed in
any living space.
• Installation of any components not manufactured
or approved by Jøtul or failure to meet all clearance
requirements will void all warranties and could
result in property damage, bodily injury, or serious
fire.
• Never modify any venting component, or use any
damaged venting product.
• THE GAS APPLIANCE AND VENT SYSTEM MUST
BE VENTED DIRECTLY TO THE OUTSIDE OF THE
BUILDING, AND NEVER ATTACHED TO A CHIMNEY
SERVING ANOTHER SOLID FUEL OR GAS-BURNING
APPLIANCE.
• Use vent component supplied by one of the vent
manufacturers listed on page 5 of this manual.
Do not mix components from different manufac-
turers in a single installation.
138727_Rev_F 8/9/11
9