Care And Maintenance; Errors And Self Diagnosis - Fujitsu ART36AL(3)H Operating Manual

Duct type
Table of Contents

Advertisement

CARE AND MAINTENANCE

CAUTION!
Installing the Air Filter
Be sure the filter is always installed in the inlet air grille of the indoor unit.
Filters can be purchased through your local dealer.
Cleaning the Air Filter
If dirt is allowed to collect in the air filter, the airflow will be reduced, leading to reduced performance, and increased
operation noise. Be sure to clean the filters regularly.
How to Cleaning
Use a vacuum cleaner to remove dust and dirt from the air filter, or wash in a synthetic detergent. After washing, dry in a
shaded place, then reinstall.
G When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.
G When cleaning the unit's body, do not use water hotter than 40°C, harsh abrasive cleansers, or volatile agents like ben-
zene or thinner.
G Do not expose the unit body to liquid insecticides or hairsprays.
G If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.

ERRORS AND SELF DIAGNOSIS

NON STOP
CLOCK
OFF ON
TIMER
TIMER
PROGRAM
REPEAT
TIMER
SET
MODE
TIME
CLOCK ADJUST
ENERGY
SAVE
If there is a problem with the air conditioner, it will stop
running and "EE: EE" will be displayed instead of the clock.
1. If the operation lamp is on then press the START/
STOP buttons to turn it off.
2. Press the ENERGY SAVE and the ZONE CONTROL
buttons at the same time for more than three seconds
to start the self diagnosis check.
An error code will be displayed in the clock display
area.
3. Press the ENERGY SAVE and the ZONE CONTROL
buttons again for more than three seconds to end the
self diagnosis check.
10
G Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
G Turn off the electrical breaker.
G A fan operates at high speed inside the unit, and personal injury could result.
TEMP.
FAN AUTO
°
OFF
HEAT
FAN HIGH
ON
FAN
FAN MED
COOL
FAN LOW
ON
OFF
DEFROST
TEST
SET
FAN
MASTER
TEMP.
CONTROL
CONTROL
ZONE
START
CONTROL
STOP
Error Code
Communication error
(indoor unit
Communication error
(indoor unit
Room temperature sensor open.
Room temperature sensor shorted.
Indoor heat exchanger temperature
sensor open.
Indoor heat exchanger temperature
sensor shorted.
Outdoor heat exchanger temperature
sensor open.
Outdoor heat exchanger temperature
sensor shorted.
Outdoor temperature sensor open.
Outdoor temperature sensor shorted.
Discharge pipe temperature sensor open.
Discharge pipe temperature sensor
shorted.
High pressure abnormal.
Discharge pipe temperature abnormal.
Error
remote controller)
t
s
outdoor unit)
t
s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents