6.6.5 Disarm on Completion

When the alignment process is complete, the installer MUST REMEMBER TO DISARM
BOTH UNITS in the link, as described in Section 7.7 "Installation Wizard". This is necessary
in order to:
Turn off the audible alignment aid (section 7.7.6 "Disarm")
Enable Adaptive Modulation
Fully enable Advanced Spectrum Management with i-DFS
Clear unwanted installation information from the various systems statistics
Store the link range for fast link acquisition on link drop
Enable higher data rates
NOTE
After 24 hours, the units will be disarmed automatically, provided that they are armed
and that the link is UP.