Emissions Information; Product Specifications; Operation; Know The Generator - Generac Power Systems XG 6500 Watt Series Owner's Manual

Xg 6500/8000 watt series
Table of Contents

Advertisement

Available languages

Available languages

1.3 EMISSIONS INFORMATION

The Environmental Protection Agency (EPA) requires that
this generator comply with exhaust and evaporative emission
standards. This generator is certified to meet the applicable EPA
emission levels on gasoline. The emission control system on this
generator consists of the following:
• Fuel System
~ Carburetor
~ Fuel Tank/cap
~ Fuel Lines
~ Evaporative Vent Lines
• Exhaust System
~ Exhaust Manifold
~ Muffler
It is important to perform the service specified in the Maintenance
Schedule to ensure that the generator complies with the applicable
emission standards for the duration of its useful life. Additionally,
emissions critical maintenance must be performed as scheduled
in order for the Emissions Warranty to be valid. Emissions critical
maintenance consists of servicing the air filter and spark plugs in
accordance with the Maintenance Schedule. Service and repairs
may be performed by any capable person or repair shop.

1.4 PRODUCT SPECIFICATIONS

1.4.1 GENERATOR SPECIFICATIONS
Assembled Dimensions: (Length X Width X Height) :
800mm [31.5"] X 648mm [25.5"] X 711mm [28"]
Extended Length: 1232mm [48.5"]
Model # ......................................................................005846, 005847
Rated Max. Power ...................................................................8.0 kW**
Surge Power ................................................................................10 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................33.3 Amps**
Current @ 120V .............................................................66.7 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
Unit Weight ................................................................ 100 Kg [219 lbs.]
Model # ......................................................................005845, 005798
Rated Max. Power ...................................................................7.0 kW**
Surge Power .............................................................................8.75 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................29.2 Amps**
Current @ 120V .............................................................58.3 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
Unit Weight ................................................................ 100 Kg [219 lbs.]
• Air Induction System
~ Intake Pipe/manifold
~ Air Filter
• Ignition System
~ Spark plug
~ Ignition module
• Exhaust System
~ Exhaust Manifold
Model # ....................................................................................005796
Rated Max. Power ...................................................................6.5 kW**
Surge Power .............................................................................8.13 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................27.1 Amps**
Current @ 120V .............................................................54.2 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Unit Weight ................................................................ 102 Kg [225 lbs.]
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.
1.4.2 ENGINE SPECIFICATIONS
Displacement ............................................................................... 407cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Part No. ...................................................................0E7585
Spark Plug Gap ............................................... 0.030 inch or (0.76 mm)
Gasoline Capacity ............................................................ 9 U.S. gallons
Oil Type.................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ................................................ w/ Filter Change = 1.5 Qts.
Oil Filter Part No. . ....................................................................070185B
Run Time/Fuel Consumption-1/2 Load .. 10 Hours / .73 gallons per hour

2.1 KNOW THE GENERATOR

Read the entire Owner's Manual and Safety Rules before
operating this generator.
Compare the generator to Figures 3 through 6 to become
familiarized with the locations of various controls and adjustments.
Save this manual for future reference.
1. Choke Knob – Used when starting a cold engine (Pull/Push).
2. Engine Switch – Controls the operation of the generator. On
electric start models the switch is Start/Run/Stop. On recoil
start models the switch is On/Off.
3. Fuel Shut Off – Valve between fuel tank and carburetor. Turn
off and run carburetor out of fuel for extended storage.
4. Panel LED's – Provide illumination of the control panel while
the generator is operating.
5. 120/240 Volt AC, 30 Amp Locking Receptacle – Supplies
electrical power for the operation of 120 and/or 240 Volt AC,
30 Amp, single-phase, 60 Hz, electrical lighting, appliance,
tool and motor loads.
6. 120 Volt AC, 20 Amp, GFCI Duplex Receptacle – Supplies
electrical power for the operation of 120 Volt AC, 20 Amp,
single-phase, 60 Hz electrical lighting, appliance, tool and
motor loads. It also provides protection with an Integral
Ground Fault Circuit Interrupter, complete with a press to
"Test" and "Reset" button.
7. Circuit Breakers (AC) – Each 20 Amp receptacle is provided
with a push-to-reset circuit breaker to protect the generator
against electrical overload.

Operation

w/o Filter Change = 1.2 Qts.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xg 8000 watt series584658475796

Table of Contents