Combination; Standard Supplied Accessories - Daikin RXQ5P7W1B Installation Manual

Vrv iii system air conditioner
Hide thumbs Also See for RXQ5P7W1B:
Table of Contents

Advertisement

1.1.

Combination

The indoor units can be installed in the following range.
Always use appropriate indoor units compatible with R410A.
To learn which models of indoor units are compatible with
R410A, refer to the product catalogs.
Pay attention when connecting outdoor units in multi
combination. RXYQ-M
RXY(H)Q-P units.
Total capacity/quantity of indoor units
Standard combination of outdoor units
(a)
RX(Y)Q5
RX(Y)Q8
(a)
RX(Y)Q10
(a)
RX(Y)Q12
(a)
RX(Y)Q14
(a)
RX(Y)Q16
(a)
RX(Y)Q18
(a)
RXYQ20
= RXYQ8 + RXYQ12
RXYQ22
= RXYQ10 + RXYQ12
RXYQ24
= RXYQ12 + RXYQ12
RXYQ26
= RXYQ8 + RXYQ18
RXYQ28
= RXYQ10 + RXYQ18
RXYQ30
= RXYQ12 + RXYQ18
RXYQ32
= RXYQ14 + RXYQ18
RXYQ34
= RXYQ16 + RXYQ18
RXYQ36
= RXYQ18 + RXYQ18
RXYQ38
= RXYQ8 + RXYQ12 + RXYQ18
RXYQ40
= RXYQ10 + RXYQ12 + RXYQ18
RXYQ42
= RXYQ12 + RXYQ12 + RXYQ18
RXYQ44
= RXYQ8 + RXYQ18 + RXYQ18
RXYQ46
= RXYQ10 + RXYQ18 + RXYQ18
RXYQ48
= RXYQ12 + RXYQ18 + RXYQ18
RXYQ50
= RXYQ14 + RXYQ18 + RXYQ18
RXYQ52
= RXYQ16 + RXYQ18 + RXYQ18
RXYQ54
= RXYQ18 + RXYQ18 + RXYQ18
(a) = main unit
Standard combination of outdoor units
(a)
RXYHQ12
RXYHQ16 = RXYQ8 + RXYQ8
RXYHQ18 = RXYQ8 + RXYQ10
RXYHQ20 = RXYQ8 + RXYHQ12
RXYHQ22 = RXYQ10 + RXYHQ12
RXYHQ24 = RXYQ8 + RXYQ8 + RXYQ8
RXYHQ26 = RXYQ8 + RXYQ8 + RXYQ10
RXYHQ28 = RXYQ8 + RXYQ10 + RXYQ10
RXYHQ30 = RXYQ8 + RXYQ10 + RXYHQ12
RXYHQ32 = RXYQ8 + RXYHQ12 + RXYHQ12 400~1040
RXYHQ34 = RXYQ10 + RXYHQ12 + RXYHQ12 425~1105
RXYHQ36 = RXYHQ12 + RXYHQ12 + RXYHQ12 450~1170
(a) = main unit
RX(Y)Q5-10-12P7W1B + RXQ8P7W1B + RXYQ8P8W1B +
RXYHQ12P8W1B + RX(Y)Q14~18P7W1BA
VRVIII System air conditioner
4PW48461-1
units
are
NOT
compatible
Total
Total
capacity of
quantity of
indoor units
indoor units
62.5~162.5
100~260
125~325
150~390
175~455
200~520
225~585
250~650
275~715
300~780
325~845
350~910
375~975
400~1040
425~1105
450~1170
475~1235
500~1300
525~1365
550~1430
575~1495
600~1560
625~1625
650~1690
675~1755
Total
Total
capacity of
quantity of
indoor units
indoor units
150~390
200~520
225~585
250~650
275~715
300~780
325~845
350~910
375~975
NOTE
with
12
20
25
30
35
40
45
40
44
48
52
56
60
64
64
64
61
1.2.

Standard supplied accessories

64
See location 1 in
64
accessories are supplied with the unit.
64
Installation manual
64
Operation manual
64
Fluorinated greenhouse gases label
64
Multilingual fluorinated greenhouse
gases label
64
See location 2 in
64
accessories are supplied with the unit.
Unit type
5~18 Hp
30
5~10 Hp
32
12~18 Hp
36
Unit type
40
5~18 Hp
44
5~10, 14, 16 Hp
39
12, 18 Hp
42
45
(a) = main unit
48
52
55
58
The table above shows the possible total capacity
and number of possible indoor units when
configured in a standard combination.
Refer to the service manual for more details when
using a configuration other than a standard
combination.
If the total capacity of the connected indoor units
exceeds the capacity of the outdoor unit, cooling
and heating performance may drop when running
the indoor units.
Refer to the section on performance charac-
teristics in the Engineering Data Book for details.
There are restrictions on the refrigerant pipe
connection order between outdoor units during
installation in case of a multiple outdoor unit
system.
Install according to the following restrictions.
The capacities of outdoor units A, B, and C must
fulfill the following restriction conditions: A≥B≥C.
A
B
1 2
3
1
To indoor units
2
Outdoor unit multi connection piping kit (first
branch)
3
Outdoor unit multi connection piping kit
(second branch)
figure 24
for reference to where following
figure 24
for reference to where following
(a)
Gas side accessory pipe
Item
(a)
Liquid side accessory pipe
Item
C
1
1
1
1
Quantity
1
1
1
Quantity
1
1
1
Installation manual
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents