Service Code
Failure Description
Shown on Display
F-56
Wrong or invalid con guration.
Service Code
Failure Description
Shown on Display
F-56
Wrong or invalid con guration.
F-58
Wrong or invalid con guration
F-58
Wrong or invalid con guration
F-60
UI does not work
F-60
UI does not work
F-61
Power control board does not
work
F-61
Power control board does not
work
C-81, C-82
Over temperature
C-81, C-82
Over temperature
Troubleshooting (continued)
Type of Failure
Type 3
Type of Failure
Type 3
Type 2
Type 2
Type 3
Type 3
Type 2
Type 2
Type 2
Type 2
go to Step 11.
11. Disconnect power.
12. Check the continuity of the fuses on the EMI board. If either of the
fuses is blown, replace with a new one.
13. Replace all parts and panels before operating.
14. Reconnect power and check that it is working. If it is not working,
go to Step 15.
15. Disconnect power.
16. Change both control boards.
17. Replace all parts and panels before operating.
Repair Suggestions
18. Reconnect power and recon gure the cooktop following the
directions in "Manual Con guration Mode." Check that it is
working. If it is not working, go to Step 19.
1.
Disconnect power.
19. Disconnect power.
2.
Reconnect power.
20. Change the User Interface.
3.
Recon gure the cooktop following the directions in "Manual
21. Replace all parts and panels before operating.
Con guration Mode."
22. Reconnect power and recon gure the cooktop following the
Repair Suggestions
4.
If the issue is not xed, disconnect power.
directions in "Manual Con guration Mode."
5.
Replace the User Interface.
6.
Replace all parts and panels before operating.
1.
Disconnect power.
7.
Reconnect power.
2.
Reconnect power.
3.
8.
Recon gure the cooktop following the directions in "Manual
Recon gure the cooktop following the directions in "Manual
Con guration Mode."
Con guration Mode."
4.
If the issue is not xed, disconnect power.
1.
Disconnect power.
5.
Replace the User Interface.
2.
Reconnect power.
6.
Replace all parts and panels before operating.
3.
Recon gure the cooktop following the directions in "Manual
7.
Reconnect power.
Con guration mode."
8.
Recon gure the cooktop following the directions in "Manual
4.
If the issue is not xed, disconnect power.
Con guration Mode."
5.
Replace the power control board.
6.
Replace all parts and panels before operating.
1.
Disconnect power.
7.
Reconnect power.
2.
Reconnect power.
8.
Recon gure the cooktop following the directions in "Manual
3.
Recon gure the cooktop following the directions in "Manual
Con guration Mode."
Con guration mode."
4.
If the issue is not xed, disconnect power.
1.
Disconnect power.
5.
Replace the power control board.
2.
Replace the User Interface.
6.
Replace all parts and panels before operating.
3.
Replace all parts and panels before operating.
7.
Reconnect power.
4.
Reconnect the power.
8.
Recon gure the cooktop following the directions in "Manual
5.
Recon gure the cooktop following the directions in "Manual
Con guration Mode."
Con guration Mode."
1.
Disconnect power.
1.
Disconnect power.
2.
Replace the User Interface.
2.
Check that the cables between the User Interface and the power
3.
Replace all parts and panels before operating.
control board are not damaged and are rmly plugged in.
4.
Reconnect the power.
3.
Check for 240 Volts AC at the J1 connector on the power control
5.
Recon gure the cooktop following the directions in "Manual
board by completing the following steps.
Con guration Mode."
4.
Connect voltage measurement equipment.
5.
Reconnect power and con rm voltage reading. If voltage is not
1.
Disconnect power.
correct, disconnect power and have a quali ed electrician check
2.
Check that the cables between the User Interface and the power
the home power supply.
control board are not damaged and are rmly plugged in.
6.
If voltage is correct, disconnect power and replace the cable
3.
Check for 240 Volts AC at the J1 connector on the power control
between the User Interface and the power control board.
board by completing the following steps.
7.
Replace all parts and panels before operating.
4.
Connect voltage measurement equipment.
8.
Reconnect power.
5.
Reconnect power and con rm voltage reading. If voltage is not
9.
Recon gure the cooktop following the directions in "Manual
correct, disconnect power and have a quali ed electrician check
Con guration Mode."
the home power supply.
6.
If voltage is correct, disconnect power and replace the cable
Not enough ventilation: Check the cooktop installation according to
between the User Interface and the power control board.
the Installation Instructions. In particular, check the blower intakes.
7.
Replace all parts and panels before operating.
8.
Reconnect power.
9.
Recon gure the cooktop following the directions in "Manual
Con guration Mode."
Not enough ventilation: Check the cooktop installation according to
the Installation Instructions. In particular, check the blower intakes.
6-6