Section 0
Contents
4-4-15 EEPROM error ...................................................................................................................................................................................4-42
4-4-16 Option error of the Remote Controller for an Indoor Unit ....................................................................................4-43
4-4-17 Error due to confused use of Fahrenheit and Celsius ..............................................................................................4-43
4-4-18 Simultaneous opening of Cooling/heating MCU SOL Valves 1
4-4-20 SPI Feedback Error .........................................................................................................................................................................4-46
4-4-21 Outdoor Unit Pipe Inspection Error ....................................................................................................................................4-47
4-4-23 Communication Error between Indoor and Outdoor Units after Tracking ................................................4-49
4-4-25 Communication Error between MCU and Outdoor Unit ......................................................................................4-51
4-4-26 Internal Communication error of the Outdoor Unit C-Box ..................................................................................4-52
4-4-27 Internal PCB Communication error of the Outdoor Unit C-Box ........................................................................4-53
4-4-31 MCU branch part setup error - non-installed address setup..............................................................................4-57
4-4-32 Setup Error for MCU Branch part - Setup Error for MCU Quantity Used .....................................................4-58
4-4-33 MCU branch part setup error - Overlapping Indoor unit Address setup ...................................................4-59
4-4-37 Outdoor Temperature Sensor Error ....................................................................................................................................4-63
4-4-38 Outdoor Temperature dislocation error ...........................................................................................................................4-64
4-4-39 Cond Out Temperature Sensor Error (Open/Short) ..................................................................................................4-65
4-4-40 Outdoor Cond Out sensor breakaway error .................................................................................................................4-66
4-4-41 Digital Compressor Discharge Temperature Sensor Error (OPEN/SHORT) .................................................4-67
4-4-43 Compressor Discharge or Top 1/2 Temperature sensor error .............................................................................4-69
4-4-45 E269 : Suction Temperature sensor breakaway error .............................................................................................4-71
4-4-46 SUMP Temperature Sensor Error (OPEN/SHORT) ......................................................................................................4-72
4-4-47 High Pressure sensor error (Open/Short) ........................................................................................................................4-73
4-4-48 Low Pressure sensor error (Open/Short)..........................................................................................................................4-74
4-4-49 Suction Temperature sensor error (Open/Short) ........................................................................................................4-75
4-4-50 Liquid Pipe Temperature sensor error (Open/Short) ................................................................................................4-76
4-4-51 EVI In Temperature sensor error (Open/Short) .............................................................................................................4-77
4-4-52 EVI Out Temperature sensor error (Open/Short) ........................................................................................................4-78
4-4-53 Suction-2 Temperature Sensor Error (OPEN/SHORT)...............................................................................................4-79
4-4-54 E407 : Comp. Down due to High Pressure Protection Control ...........................................................................4-80
4-4-55 E410 : Comp. Down due to Low Pressure Protection Control ............................................................................4-81
4-4-56 Sump Sensor Error Due to Protection Control .............................................................................................................4-82
4-4-57 E416 : Comp. Down due to Compressor Discharge Temperature sensor ...................................................4-83
4-4-58 3-phase Input Wiring error .......................................................................................................................................................4-84
4-4-59 E428 : Comp. Down by Compression Ratio Control .................................................................................................4-85
4-4-60 EVI EEV Open error ........................................................................................................................................................................4-86
4-4-61 Refrigerant Leakage Error .........................................................................................................................................................4-87
4-4-64 CCH Malfunction and Sump Sensor Miswiring Error ...............................................................................................4-90
4-4-65 Fan starting error ............................................................................................................................................................................4-91
4-4-66 Fan lock error ....................................................................................................................................................................................4-92
4-4-67 Momentary Blackout error .......................................................................................................................................................4-93
4-4-68 Outdoor Fan Motor overheating ..........................................................................................................................................4-94
4-4-69 Outdoor Unit Fan Motor RPM Error ....................................................................................................................................4-95
4-4-70 Fan IPM Overheat error ..............................................................................................................................................................4-96
4-4-71 Over-Voltage Error of an Outdoor Fan Motor ...............................................................................................................4-97
4-4-72 Counter-Rotation Error of an Outdoor Fan Motor .....................................................................................................4-97
2