Outdoor Temperature Dislocation Error - Samsung AM009FN1DCH/AA Service Manual

System air conditioner indoor unit
Hide thumbs Also See for AM009FN1DCH/AA:
Table of Contents

Advertisement

Troubleshooting

4-4-38 Outdoor Temperature dislocation error

1. How to check
Is an outdoor temperature sensor
connector dislocated from the PCB?
After separating the outdoor temperature sensor
connector from the PCB, measure the resis-
tance value between both terminals.
Does the resistance value
temperature table to the next?
Restart after replacing the PCB
4-64
Yes
Yes
greatly deviate from the
Yes
No
Restart after connecting
the connector to the PCB.
Temperature
(°C)
-10
No
As it is due to a problem with
the outdoor temperature sensor,
replace it.
Resistance
(KΩ)
70
2.2
60
3.0
50
4.2
40
5.8
30
8.3
21
12.1
10
18.0
0
27.3
43.0
Samsung Electronics