Samsung AM009FN1DCH/AA Service Manual page 115

System air conditioner indoor unit
Hide thumbs Also See for AM009FN1DCH/AA:
Table of Contents

Advertisement

Diagnosis and Adjustment (Error Code)
Error code related to the Communications / Settings / HW
CODE
Communication error between indoor and outdoor units (installation number setting error,
E-201
repeated indoor unit address, indoor unit communication cable error)
Communication error between indoor and outdoor units (Communication error on all indoor
E-202
unit, outdoor unit communication cable error)
E-203
Communication error between main and sub outdoor units
E-205
Communication error on all PBA within the outdoor unit C-Box, communication cable error
E206-C001: HUB PBA communication error / E206-C002: FAN PBA communication errorE206-C003:
E-206
INV1 PBA communication error / E206-C004: INV2 PBA communication error
E-211
When single indoor unit uses 2 MCU ports that are not in series.
If the rotary switch (on the MCU) for address setting of the indoor unit has 3 or more of the same
E-212
address
When total number of indoor units assigned to MCU is same as actual number of installed indoor
E-213
units but there is indoor unit that is not installed even though it is assigned on MCU
When number of MCU is not set correctly on the outdoor unit or when two or more MCU was
E-214
installed some of them have the same address
E-215
When two different MCU's have same address value on the rotary switch
E-216
When indoor unit is not installed to a MCU port but the switch on the port is set to On.
hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch
E-217
on the port is set to Off
When there's at least one or more actual number of indoor unit connection compared to number
E-218
of indoor units assigned to MCU
E-219
Error on temperature sensor located on MCU intercooler inlet (Short or Open)
E-220
Error on temperature sensor located on MCU intercooler outlet (Short or Open)
E-221
Error on outdoor temperature sensor of outdoor unit (Short or open)
E-231
Error on COND OUT temperature sensor of main outdoor unit (Short or Open)
E-241
COND OUT sensor is detached
E-251
Error on discharge temperature sensor of compressor 1 (Short or Open)
E-257
Error on discharge temperature sensor of compressor 2 (Short or Open)
E-262
Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe
E-263
Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe
E-266
Top sensor of compressor 1 is detached
E-267
Top sensor of compressor 2 is detached
E-269
Suction temperature sensor is detached from the sensor holder on the pipe
E-276
Error on top sensor of compressor 1 (Short or Open)
E-277
Error on top sensor of compressor 2 (Short or Open)
E-291
Refrigerant leakage or error on high pressure sensor (Short or Open)
E-296
Refrigerant leakage or error on low pressure sensor (Short or Open)
E-308
Error on suction temperature sensor (Short or Open)
Samsung Electronics
(cont.)
Explanation
Troubleshooting
4-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents