Resetting the User Memory to the Initial
Factory Settings—[JOB] (Factory Set)
In the Utility Job mode, you can restore this synthesizer's
User memory (page 34) to the factory default settings
(Factory Set). Please note that the setting of the Power On
Auto Factory Set on this display will be stored automatically
by executing the Factory Set.
NOTICE
The Factory Set operation will erase all the data you've created and
stored to User Memory, including the Waveform data on the
optional Flash Memory Expansion Module FL512M/FL1024M (if
installed). To prevent data loss, be sure to save all important data
to a USB storage device or to a computer connected to the same
network as the MOTIF XF (page 241) before executing the Factory
Set operation.
All
When this is set to on, pressing the [ENTER] button will
restore all the data of this synthesizer's User memory (page
34) to the factory default settings (Factory Set).
When this is set to off, pressing the [ENTER] button will
restore only the following data to the factory default
settings: All the Voices (A01 – H16) of the User Bank 1
(USR1) and Voices A01 – A08 of the User Drum Bank
(UDR).
Settings: on, off
Power On Auto Factory Set
When this parameter is set to "on," turning the power on will
restore the User memory to the factory default settings and
load the demo songs and demo patterns. Normally, this
should be set to "off."
Settings: on, off
NOTICE
When the Power On Auto Factory Set parameter is set to "on,"
turning the power off erases all the User memory data such as
Voice, Performance, Song, Pattern and Utility settings.
For instructions on executing the Factory Set Job, refer to
the Owner's Manual.
Sequencer Settings—[SEQ SETUP]
In the Song mode, Pattern mode or Performance mode,
pressing the [SEQ SETUP] button calls up the display for
setting the overall sequencer parameters. After setting
these, press the [STORE] button to store the settings of
both the Sequencer Setup parameters and the Utility
parameters.
NOTICE
All Sequencer Setup settings will be lost if the power is turned off
without storing.
n In the Voice mode and Master mode with the Mode parameter
(page 214) set to "Voice," the [SEQ SETUP] button cannot be
used.
Metronome Settings—[F1] Click
From this display you can set the parameters related to the
click sound (metronome) that is used during recording or
playback in the Song/Pattern/Performance mode.
n Since the click sound is created with the internal tone
generator, using click playback affects the overall polyphony
of this synthesizer.
Mode
Determines whether and when the metronome click will
sound.
Settings: off, rec, rec/play, always
off
The click will not sound.
rec
The click will sound during Song/Pattern/Performance recording only.
rec/play
The click will sound during recording and playback.
always
The click will always sound in the Song/Pattern mode.
Beat
Determines on which beats the metronome click will sound.
��
��
Settings:
(16th notes),
(8th notes),
��
��
(harf notes),
(whole notes)
Volume
Determines the click sound volume.
Settings: 0 – 127