8 [AV MUTE]
Displays the AV mute status.
9 [VOLUME]
Displays the volume status.
10 [INPUT]
Displays the status of the selected input.
11 [INTAKE AIR TEMPERATURE]
Displays the status of the air intake temperature of the
projector.

Error information page

When [Error (Detail)] or [Warning (Detail)] is displayed in the self-diagnosis display of the [Projector status] screen, click it to
display the error/warning details.
f The projector may go into the standby status to protect the projector depending on the contents of the error.
1 Self-diagnosis result display
Displays the item check results.
[OK]: Indicates that operation is normal.
r [FAILED] items displayed when a problem occurs
Parameter
[FAN]
[FAN(INTAKE1)]
[FAN(INTAKE2)]
[FAN(INTAKE3)]
[FAN(INTAKE4)]
[FAN(EXHAUST)]
[FAN(LAMP)]
[INTAKE AIR TEMPERATURE]
[EXHAUST AIR TEMPERATURE]
[LAMP REMAIN TIME]
[LAMP STATUS]
[APERTURE (CONTRAST-SHUTTER)]
[AIR FILTER]
Chapter 4 Settings - [NETWORK] menu
12 [EXHAUST AIR TEMPERATURE]
13 [LAMP RUNTIME]
14 [SELF TEST]
15 [PROJECTOR RUNTIME]
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
Trouble has occurred in the intake fan 1.
Trouble has occurred in the intake fan 2.
Trouble has occurred in the intake fan 3.
Trouble has occurred in the intake fan 4.
Trouble has occurred in the exhaust fan.
Trouble has occurred in the lamp cooling fan.
The air intake temperature is too high. The projector may be used in an operating
environment where the temperature is high, such as near a heating appliance.
The exhaust air temperature is high. The air exhaust port may be blocked.
The lamp runtime has exceeded the prescribed cumulative time, and it is now
time to replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
There is too much dust accumulated in the air filter unit. Turn off the projector
and unplug the power plug from the wall outlet, then replace the air filter unit.
Displays the status of the exhaust air temperature of the
projector.
Displays the runtime of the lamp (converted value).
Displays the self diagnostics information.
Displays the runtime of the projector.
[FAILED]: Indicates that there is a problem.
[WARNING]: Indicates that there is a warning.