Control commands via LAN
When WEB Control administrator rights password is set (Protect mode)
Connection method
1)
Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request
for connection to the projector.
f Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page.
IP address :
Obtain from MAIN MENU → [NETWORK] → [STATUS]
Port No. :
Acquire from the WEB control → [Detailed set up] → [Command port set up] page
2)
There is a response from the projector.
Data section
Command
"NTCONTROL"
example
(ASCII string)
Data
9 bytes
length
f Mode : 1 = Protect mode
3)
Generate a 32-byte hash value from the following data using MD5 algorithm.
f "xxxxxx:yyyyy:zzzzzzzz"
xxxxxx :
Administrator rights user name for WEB CONTROL (Default user name is "admin1")
yyyyy :
Password of above administrator rights user (Default password is "panasonic")
zzzzzzzz :
8-byte random number obtained in Step 2
Command transmission method
Transmit using the following command format.
r Transmitted data
Hash value
Command
(See above
example
<Connection method>)
Data length
32 bytes
r Receive data
Command
example
Data length
r Error response
Message
Data length
106 - ENGLISH
Chapter 6 Appendix - Technical Information
Blank
Mode
' '
'1'
0x20
0x31
1 byte
1 byte
Header
'0'
0x30
1 byte
Header
'0'
0x30
1 byte
String
"ERR1"
"ERR2"
"ERR3"
"ERR4"
"ERR5"
"ERRA"
4 bytes
Blank
Random number section
"zzzzzzzz"
' '
(ASCII code hexadecimal
0x20
1 byte
Data section
'0'
Control command
0x30
(ASCII string)
1 byte
Undefined length
Data section
'0'
Control command
0x30
(ASCII string)
1 byte
Undefined length
Details
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
―
Termination symbol
number)
8 bytes
Termination symbol
Termination symbol
Termination symbol
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte