Installation
3) Installation on the floor
Installation of Mount Bracket.
• Select and mark the position for Mount Brackets and
the piping hole.
• Drill the hole for the anchor nut on the wall.
• Drill the piping hole using a ø70 hole-core drill.
• Secure the Mount Brackets on the wall with four M4
screws.
Install the indoor unit onto the Mount Brackets.
• Engage the slot at the back of the unit with Mount
Bracket.
Drill the piping hole with 70mm dia, hole core drill.
• Piping hole should be slightly slant to the outdoor side.
After Installing, reassemble detached parts.
• Hang the 'Inlet Grille' and hook the 'Inlet Hanger' to the
Hanger Screw.
• Assemble the 'Side Plates(R,L)' with 2 screws on both
left and right side.
64 Multi type Air Conditioner
From the left wall
more than 760mm
Slot
Floor mount
bracket
Wall
Indoor
Slot
Wall
From the
right wall
more than 840mm
Outdoor
Floor mount
bracket
Install plate
Piping hole