I Sticking the installation guide map and

fixing Indoor unit

1. Put an Installation Guide Map on the desired
surface.
INSTALLATION GUIDE MAP
2. Make a hole with diameter of 6mm and depth of
30-35mm when piercing a screw point.
3. Drive the fore plastic anchors into drilled points.
Plastic anchors
4. Hang the hole of product at the upper screws.
(In this time, Remove the map)
(Falling attention)
Hanger hole
(Rear side of
product)
5. Check the fixed product with light power.
6. Look at suited horizon by horizontal meter on
the horizontal setting line, and Fix lightly the
map by adhesive tape.
Horizontality
I N
S T
A I
I A T
I O
N
G U
I D
E M
A P
I N
S T
A L
L A
T I O
N
G U
I D
E M
A P
I N S
T A L
L A T
I O N
G U I
D E
M A P
I N
S T
A L
L A
T I O
N
G U
I D
E M
A P
7. Drill the piercing part for connecting pipe as
diameter 50mm. (In case of piercing rear surface)
Refer to No. 5 on this page when making a hole in the wall.
8. First, Drive the two points of the upper parts by
screws. (Leave 10mm for hanging product)
I N
S T
9. Drive the lower parts after facing the hole of
product with plastic anchors, and fix completely
the upper screws.
In case of nothing wrong in the matter,
connect the pipe and the wire.
(Installation manual reference)
I Drill a hole in the wall
• Drill the piping hole with a ø50mm hole core drill. Drill
the piping hole at either the right or the left with the hole
slightly slanted to the outdoor side.
Indoor
Installation
A L
L A
T I O
N
G U
Plastic anchors
WALL
Outdoor
Service Manual 39