Orvaldi MSII RT 6-10KVA User Manual

Parallel redundancy on-line ups

Advertisement

Parallel Redundancy On-Line UPS
1.
2.
3.
4.
5.
6.
7.
8.
6-10KVA

Table of Contents

Important Safety Instruction ............................................................................. 2
1.1. An Important Notice ......................................................................................... 2
1.2. Storage Instruction............................................................................................ 4
Product Introduction ......................................................................................... 5
2.1. General Characteristics ..................................................................................... 5
2.2. Symbols on the LCD Display Panel ................................................................. 7
2.3. Panel explanation............................................................................................ 10
2.4. Communication Port Explanation................................................................... 13
Installation and Operation............................................................................... 14
3.1. Unpacking....................................................................................................... 14
3.2. Selecting Installation Position......................................................................... 15
3.3. Installation of Accessories Kit ........................................................................ 15
3.4. Terminal Block Explanation ........................................................................... 16
3.5. Operation Test and Installation Instruction..................................................... 19
Troubleshooting Guide ................................................................................... 31
4.1. Trouble Shooting ............................................................................................ 31
Bundled Software Installation Guide.............................................................. 33
5.1. Hardware Installation...................................................................................... 33
5.2. Software Installation ....................................................................................... 33
Customer Options Slots .................................................................................. 34
6.1. R2E(2nd RS-232 ) card .................................................................................. 34
6.2. RSE(RS-485) card .......................................................................................... 34
6.3. USE(USB) card .............................................................................................. 34
6.4. DCE(Dry Contact)-B card .............................................................................. 35
6.5. SNMP Cards ................................................................................................... 36
6.6. The Installation of those Interface Cards ........................................................ 37
Hot Swappable Battery Replacement ............................................................. 38
Specifications.................................................................................................. 40
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSII RT 6-10KVA and is the answer not in the manual?

Questions and answers

Summary of Contents for Orvaldi MSII RT 6-10KVA

  • Page 1: Table Of Contents

    Table of Contents Important Safety Instruction ................2 1.1. An Important Notice ..................2 1.2. Storage Instruction.................... 4 Product Introduction ..................5 2.1. General Characteristics ..................5 2.2. Symbols on the LCD Display Panel ..............7 2.3. Panel explanation.................... 10 2.4.
  • Page 2: Important Safety Instruction

    1.1.14. Dusty, corrosive and salty environments can do damage to any UPS. 1. Important Safety Instruction 1.1.15. Install the UPS away from objects that give off excessive heat and areas 1.1. An Important Notice that are excessively wet. 1.1.1. For Parallel System installation, please refer to “MSII 6KVA Parallel 1.1.16.
  • Page 3: Storage Instruction

    1.1.25. SAVE THESE INSTRUCTIONS - This Manual Contains Important 2. Product Introduction Instructions that should be Followed during Installation and Maintenance of the UPS and Batteries. 2.1. General Characteristics 1.1.26. Intended for Installation in a Controlled Environment. 2.1.1. True online architecture continuously supplies in your critical device with a stable, regulated, transient-free pure sine wave AC Power.
  • Page 4: Symbols On The Lcd Display Panel

    2.1.12. Revolutionary battery management circuit analyzes battery discharging 2.2. Symbols on the LCD Display Panel status to adjust battery cut-off point and extend the life of batteries. 2.1.13. Intelligent temperature-controlled fan may not only extend the life of the Item Symbol Description fan, but also reduce annoying noise because of sudden fan spin.
  • Page 5 Parallel communication error ( communication Next Page wire disconnected or failure to find ID1 UPS ) Er21 in parallel system Special Function Log in /out CVCF mode with Bypass input Er24 The UPS must be operated in normal mode in Enter or Reconfirmed Er27 parallel system...
  • Page 6: Panel Explanation

    2.3. Panel explanation 2.3.2. Rear Panel Explanation 2.3.1. Front Panel Function Explanations Tower Model 6000C Model 11 12 2 3 4 5 Par allel Work Comm. Bus ONOFF P aral lel Work Comm. RS232 B us Not Inten ded to TN V C ommunic ati o n Netwo rk RS232 Not I ntended to...
  • Page 7: Communication Port Explanation

    A RS232 Port 2.4. Communication Port Explanation B Terminal Resistor for Parallel function C CAN Bus Connection Port for Parallel System The Communication port on the UPS provides true RS232 type to D Customer Options Slot 1 communicate with UPS software to remote monitoring the power and UPS status. E Customer Options Slot 2 With optional interfaces cards, which contains R2E(2 RS232), RSE(RS485),...
  • Page 8: Installation And Operation

    3. Installation and Operation 3.2. Selecting Installation Position It is necessary to select a proper environment The packing condition and the external outlook of the unit should be to install the unit, in order to minimize the inspected carefully before installation. Retain the packing material for future use. possibility of damage to the UPS and extend the life of the UPS.
  • Page 9: Terminal Block Explanation

    3.4. Terminal Block Explanation L11-N1、B-N1: the terminal for Bypass Input to provide the power source when Tower model ● the UPS is working under bypass mode. L12-N1、R-S-T-N1: the terminal for Utility Input to provide the power source OUTPUT INPUT ● when the UPS is working under Utility mode.
  • Page 10: Operation Test And Installation Instruction

    3.5. Operation Test and Installation Instruction Use Mounting Cable Tie to fix cables. ● 3.5.1. Start Up in Normal Mode Tower model 6KRT model 3.5.1.1. Open the terminal block cover on the rear panel (refer to 2.3.2) 6000C model Before start the installation, please make sure the grounding is External Battery connected properly.
  • Page 11 3.5.1.5. Then, the UPS is on Bypass Mode now and it will proceed self- test automatically. If there is no abnormal message occurred, it means the pre-startup of the UPS is successful and the charger starts to charge the batteries. 3.5.1.6.
  • Page 12 * It shows Utility input is “0” and Utility Abnormal. * It shows frequency from Utility Input. * It shows frequency from Bypass Input. 3.5.3. Check Measured Values & Figures detected by UPS 3.5.3.1. If you would like to check the measured values & figures detected by the UPS, please use scroll up and scroll down pads.
  • Page 13 3.5.4.2. Press key pad to scroll down the screen and check the UPS settings. The LCD display will show in consequence between Drawing Q1(buzzer) Drawing R1(Self-test) Drawing S1(Bypass Voltage Windows) Drawing T(Output Frequency Synchronization Window) Drawing U(Inverter Output Voltage) Drawing V1(UPS Operation Mode) Drawing W(Output Voltage Micro Tune Value) Drawing X(UPS Id)
  • Page 14 * It shows the UPS is operated in “CVCF 60Hz mode”. * It shows Frequency Window is +/-3Hz. * It shows Output Voltage Adjustment % from 0% to 3% or -0% to -3%. * It shows inverter output voltage. * It shows UPS Identification Number. * It shows the UPS is operated in “normal mode”.
  • Page 15 3.5.4.4. 3.5.5. UPS Default Settings and their alternatives 3.5.5.1. Make sure the UPS is not “On” yet. Press On Switch scroll down key pads simultaneously for approx. 3 seconds, the buzzer will sound twice, the LCD display screen shows as drawing Q1, then the UPS is under setting mode now.
  • Page 16: Troubleshooting Guide

    3.5.8.1. It is for UPS maintenance only. A Non-authorized technician is not 4. Troubleshooting Guide allowed to operate the following procedures. If there is any damage under unauthorized condition, your warranty will be void 4.1. Trouble Shooting immediately. When the UPS malfunctions during operation, you may check the followings: 3.5.8.1.1.
  • Page 17: Bundled Software Installation Guide

    5. Bundled Software Installation Guide Situation Check Items Solution UPS Red Fault Check the error code 1. Check to see if the battery connection is 5.1. Hardware Installation LED lights up shown on the LCD screen properly done, then re-charge the batteries for 8 hours to see whether the 1.
  • Page 18: Customer Options Slots

    6. Customer Options Slots 6.1. R2E(2nd RS-232 ) card VCC (+5V) D- 6.1.1. CN1 is for RS232 DB9. D+ 6.1.2. For communication protocol, please refer Ground to Chapter 2.4.1 6.1.3. Installation Position: slot1(CHA-CN4) or slot 2(CHB-CN5). 6.3.3. Installation Position: slot1(CHA-CN3) or slot 2(CHB-CN4). 6.2.
  • Page 19: Snmp Cards

    6.5. SNMP Cards 6.6. The Installation of those Interface Cards 6.5.1. SNMP/WEB card 6.5.1.1. For installation, please refer to the user’s manual attached with the card. . 6.5.1.2. Installation 6.5.1.3. Position: slot 2(CHB). 6.5.2. Net Agent II Internal Card 6.5.2.1. For installation, please refer to the user’s manual attached with the...
  • Page 20 Replacing Battery 6. Turn the battery pack handle at 90 degree as shown in Step 6. Qualified personnel allowed only. 7. Remove the battery packs from the UPS as shown in Step 7. 1. Unscrew the bottom of the front panel as indicated in Step. 1 as below. 2.
  • Page 21: Specifications

    Battery Voltage & Inner Temperature. Self-Diagnostics Upon Power-on, Front Panel Setting & 8. Specifications Software Control, 24-hour routine checking ALARMS Model 4500 / 6000 8000 / 8000P Audible and Visual Line Failure, Battery Low, Transfer to Bypass, 10000 / 10000P System Fault Conditions INPUT PHYSICAL...
  • Page 22 192321132000008...

This manual is also suitable for:

4500600080008000p1000010000p

Table of Contents