Test Instructions Sacd Mono Board; Miscellaneous Nuclei; General Start-Up Measurements; Supply Check - Marantz SA12 Service Manual

Super audio cd player
Table of Contents

Advertisement

Error code
Error description
131300
Test succeeded.
131301
I2C bus busy before start.
131302
I2C access failed.
131400
Test succeeded.
131401
I2C bus busy before start.
131402
I2C access failed.
131500
Test succeeded.
131501
I2C bus busy before start.
131502
I2C access failed.
5.4.7

Miscellaneous Nuclei

Error code Error description
140000
Test succeeded.
140001
I2C access failed.
140100
Test succeeded.
140101
I2C access failed.
140200
Test succeeded.
140300
Test succeeded.
140301
I2C bus busy.
140302
I2C device write access time-out.
140303
I2C device no write acknowledge.
140304
I2C device write failed.
140400
Test succeeded.
140401
I2C bus busy before start.
140402
I2C access failed.
140403
Setup of SCART switch failed.
140500
Test succeeded.
140501
I2C bus busy before start.
140502
I2C access failed.
140503
Setup of SCART switch failed.
140600
Test succeeded.
140601
I2C bus busy before start.
140602
I2C access failed.
140603
Setup of SCART switch failed.
140700
Test succeeded.
140701
I2C bus busy.
140702
I2C device read access time-out.
140703
I2C device no read acknowledge.
140704
I2C device read failed.
140800
Test succeeded.
140801
Setup of ColourSetup chip failed.
140802
I2C device write failed.
140900
Test succeeded.
140901
Setup of ColourSetup chip failed.
140902
I2C device write failed.
140903
I2C device read failed.
141000
Test succeeded.
141100
Test succeeded.
5.5

Test instructions SACD mono board

5.5.1
General
Impedance of measuring-equipment should be > 1MΩ
Most tests have to be done by software commands.
Together with the software command you will find a Ref.#
nbr. This is the number of the diagnostic nucleus used for
this test. More detailed information can be found in the
description of the command mode interface.
Levels: Most measurements are digital measurements.
The high and low levels in this document got to have next
specification: low
(LVTTL) LOW : < 0.4V (TTL) HIGH: > 4.5V (TTL)
All voltages marked with "stby" have to stay on during
standby.
Because all clocks are derived from the SACD clock
(384FS_in) from the DAC board, this board should
always be connected to the mono board.
The linear power supply is switched on/off by the
STB_OUT signal from the mono board to the DAC board.
5.5.2

General start-up measurements

Supply check:

1. Measure the voltages on the pins of the connector 1600
with a multimeter.
2. Also check the following power supplies:
pin
TP
1600-1
F604
1600-2
F604
1600-3
F631
1600-4
F614
1600-5
F615
1600-6
F623
1600-7
F623
1600-8
F623
1600-9
F618
1600-10 F634
1600-11 F636
1600-12 F623
1600-13 F675
Testpoint F608: +3V3 (5%. (Check IC7605 in case of failure)
Testpoint F632: +3V3 (5%. (Check IC7622 in case of failure)
Testpoint F101: +9V (5%. (Check IC7109 in case of failure)
1. Current at the input of the power supply
Check the supply currents to be sure that there are no major
failures on the board.
Measure the currents flowing toward the mono board using a
Tektronix AM503B current probe on the wires between the
switch mode power supply and the connector 1600.
pin
TP
1600-1
F605
1600-2
F605
1600-3
F631
1600-4
F614
1600-5
F615
1600-6
F623
1600-7
F623
1600-8
F623
1600-9
F618
1600-10 F634
1600-11 F636
1600-12 F623
1600-13 F675
24
: < 0.3V (LVTTL) high : > 3.0V
Signal_name Voltage
+3V3
+3V3
+3V3
+3V3
+5V
+5V (0V during standby)
+5Vstby
+5V
+6Vstby
+6V
GND
0V
GND
0V
GND
0V
-8Vstby
-8V
STB_CONT
0V (+5V during standby)
+12Vstby
+12V
GND
0V
PWR_FAIL
+2.1V (1.4V during
standby)
Signal_name measured
+3V3
560 mA
+3V3
+5V
510 mA
+5Vstby
2 mA
+6Vstby
< 1 mA
GND
GND
GND
-8Vstby
54 mA
STB_CONT
+12Vstby
90 mA
GND
PWR_FAIL