10-1. Installation Diagram of Indoor and Outdoor Units
...
Active carbon
catechin
Active carbon
catechin
ˆ
Pan head
wood screw
Batteries
Wireless remote control
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (− ) positions.

10. INSTALLATION PROCEDURE

Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Before installing the wireless remote controller
2 Wireless remote controller
Hook
Installation
plate
Shield pipe
Saddle
Extension
drain hose
(Not available,
provided by installer)
44
FILE NO. SVM-10017
For the rear left and left piping
Insert the cushion between the
indoor unit and wall, and tilt the
indoor unit for better operation.
Do not allow the drain hose to
get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left,
rear right, right,bottom right
or bottom left.
Right
Rear
right
Bottom
Rear
right
left
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam