Specification Of Electrical Parts; Indoor Unit; Outdoor Unit - Toshiba RAS-107SKV-E3 Service Manual

Split type
Table of Contents

Advertisement

6. SPECIFICATION OF ELECTRICAL PARTS

6-1. Indoor Unit

No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
Switching transformer (T01)
4
Microcontroller unit (IC81)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge diode (DB01)
8
Capacitor (C27)
9
Fuse (F01)
10
Regulator IC (IC02)
11
Varistor (R01)
12
Louver motor

6-2. Outdoor Unit

No.
Parts name
1
SC coil
(Noise filter)
2
DC-DC transformer
3
Reactor
4
Outside fan motor
5
Fan control relay
Outside air temp.
6
sensor (TO sensor)
Heat exchanger temp.
7
sensor (TE sensor)
Dischenge temp.
8
sensor (TD sensor)
Terminal block (5P)
9
9
Fuse
11
Electrolytic capacitor
12
IGBT
13
Compressor
14
Rectifier
15
Running capacitor
(for fan motor)
16
4-WAY valve coil
Type
AFN-220-20-4D
ST-02
µPD780076GK-703-9ET-A
SS11V-R06270
DB105G
EKMH401VSN470MP20S 47µF, 400V
FJL250V3.15A
S7805PIC
SR561K14DO
24BYJ48
Model name
L01
GET-04051
L03
GET-04052
SWT-72
CH-69-Z-T
WLF-240-20A-1
G5NB-1A-CA
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-5B
For protection of switching power source
For protection of inverter input overcurrent
LLQ2G501KHUATF
GT15J321
DA89X1C-23EZ
D15XB60-4001
DS451155NPQB
STF-01AJ646A1
– 18 –
FILE NO. SVM-10017
Specifications
AC Motor with 145°C thermo fuse
10 kΩ at 25°C
10 kΩ at 25°C
27 m H, AC 0.6A
1A, 600V
3.15A, 250 V
5VDC, 0.5A
560V
DC 12V
Rating
0.6mH, 15A
10A, 2mH
Primary side DC280V, Secondary
side 7.0 V x 1, 12 V x 1, 17V x 2
L=19mH, 10A
20W
Coil DC12V Contact 3A/125VAC
10kΩ (25°C)
10kΩ (25°C)
62kΩ (20°C)
20A, AC250V
3.15A, AC250V
25A, AC250V
500µF, DC 400 V x 3 pieces
15A, 600V
3-phases 4-poles 750W
15A, 600V
AC 450V~, 1.5µF
AC 220-240V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-107sav-e3Ras-107sav-eRas-107skv-e

Table of Contents