Specifications Of Electrical Parts - Toshiba RAS-10N3KVR-E Service Manual

Toshiba split type air conditioners service manual
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
Parts name
No.
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (5P)
8
Compressor
9
Coil for PMV
10
Coil for 4-way valve
Part s n ame
Type
AFN-220-20-4D
( - )
(
)
-
MSBPC20F04
Mode l na me
CH-69
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
DA89X1C-23FZ2
CAM-MD12TCTH-5
STF-01AJ646A1
19
FILE NO. SVM-12057
Specif icat io ns
AC240V, 20W
10k
at 25°C
10kΩ at 25°C
Output (Rated) 1W, 16 poles, DC12V
Rating
L = 19mH, 10A
DC140V, 43W
10k
(25°C)
62k
(20°C)
10k
(25°C)
10k
(25°C)
AC250V, 20A
3-phases 4-poles
DC12V
AC220-240V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10n3avr-eRas-13n3kvr-eRas-13n3avr-e