Perform these adjustments when any of the following are replaced: CRT, defl ection yoke, D-board, and whenever touch-ups are required.
REQUIRED EQUIPMENT: NTSC generator with dot pattern and cross-hatch pattern.
SET-UP CONDITION:
Display Mode: FULL (NTSC)
Picture mode: STANDARD (select the STANDARD mode from the user menu, then press the RESET button on the remote control to set the
STANDARD settings to the factory settings).
BRIGHTNESS: 50%
PICTURE: 50%
VERTICAL CORRECTION: set to zero (from the user menu).
PROCEDURE:
1. Make sure the TV power is off, then disable the dynamic convergence
circuit by unplugging CN5510 from the D-board.
2. Turn the set on and display the dot pattern.
CN5510
3. Adjust the H-STAT control on the C-board (RV9001) to horizontally
converge the red, green, and blue dots in the center of the screen.
C Board
SECTION 5. STATIC CONVERGENCE ADJUSTMENTS
TILT CORRECTION: set to zero (from the user menu).
H-STAT control
4. Lock the H-STAT control with locking paint.
5. Adjust the V-STAT magnets on the defl ection yoke to vertically
converge the red, green, and blue dots in the center of the screen.
6. Adjust the BMC magnets and the V-STAT magnets for the best
possible alignment of the red, green, and blue dots.
— 24 —
B
B
R
R
R
R
B
KD-34XBR2