Service Position - Sony TRINITRON KD-34XBR2 Service Manual

Trinitron color television
Hide thumbs Also See for TRINITRON KD-34XBR2:
Table of Contents

Advertisement

1-4. SERVICE POSITION

1
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove
the anode cap. Short between the anode and CRT coated earth ground strap.
NOTE: After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT.
REMOVAL PROCEDURES
a
Turn up one side of the rubber cap in the
direction indicated by arrow a .
HOW TO HANDLE AN ANODE CAP
1. Do not use sharp objects which may cause damage to the surface of the anode
cap.
2. To avoid damaging the anode cap, do not squeeze the rubber covering too hard.
A material fi tting called a shatter-hook terminalis built into the rubber.
3. Do not force turn the foot of the rubber cover. This may cause the shatter-hook
terminal to protrude and damage the rubber.
ANODE CAP REMOVAL PROCEDURE
b
Use your thumb to pull the rubber cap fi rmly
in the direction indicated by arrow
— 11 —
1
Leaving the boards intact in the Main
Bracket, pull up and rotate both the A and
D boards in order to service the unit.
When one side of the rubber cap separates
.
b
from the anode button, the anode cap can
be removed by turning the rubber cap and
pulling it in the direction of arrow c .
KD-34XBR2
c
Anode Button

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents