Sony DCR-TRV240 Service Manual page 28

Digital video camera recorder
Hide thumbs Also See for DCR-TRV240:
Table of Contents

Advertisement

DCR-TRV240/TRV340
Dubbing only desired scenes – Digital program editing (on tapes)
Step 1: Connecting the VCR
You can connect both an A/V connecting cable and an i.LINK cable (DV connecting
cable).
When you use the A/V connecting cable, connect the devices as illustrated in page 70.
When you use an i.LINK cable (DV connecting cable), connect the devices as illustrated
on page 71.
If you connect using an i.LINK cable (DV connecting cable)
With a digital-to-digital connection, video and audio signals are transmitted in digital
format for high-quality editing.
Step 2: Setting the VCR to operate with the A/V connecting cable
To edit using the VCR, send the control signal by infrared rays to the remote sensor on
the VCR.
When you connect using an A/V connecting cable, follow the procedure below, steps
(1) to (4), to send the control signal correctly.
(1) Set the IR SETUP code
1 Set the POWER switch to VCR on your camcorder.
2 Turn the power of the connected VCR on, then set the input selector to LINE.
When you connect a video camera recorder, set its power switch to VCR/VTR.
3 Press MENU to display the menu settings.
4 Turn the SEL/PUSH EXEC dial to select
5 For DCR-TRV240:
Turn the SEL/PUSH EXEC dial to select VIDEO EDIT, then press the dial.
For DCR-TRV340:
Turn the SEL/PUSH EXEC dial to select TAPE in VIDEO EDIT, then press the
dial.
6 Turn the SEL/PUSH EXEC dial to select EDIT SET, then press the dial.
7 Turn the SEL/PUSH EXEC dial to select CONTROL, then press the dial.
8 Turn the SEL/PUSH EXEC dial to select IR, then press the dial.
9 Turn the SEL/PUSH EXEC dial to select IR SETUP.
0 Turn the SEL/PUSH EXEC dial to select IR SETUP code number of your VCR,
then press the dial.
Check the code in "About IR SETUP codes." (p. 76)
74
Dubbing only desired scenes – Digital program editing (on tapes)
About IR SETUP codes
The IR SETUP code is stored in the memory of your camcorder. Be sure to set the
correct code to match your VCR. The default setting is code number 3.
Brand
IR SETUP code
Sony
1, 2, 3, 4, 5, 6
Admiral (M. Wards) 89
Aiwa
47, 54, 80
Akai
49, 51
Audio Dynamic
21, 35
Bell&Howell
36
(M. Wards)
Broksonic
21, 70, 82
Canon
77, 78
Citizen
47
Craig
47, 73
Curtis Mathis
8, 77, 80
Daewoo
26, 40, 77
DBX
21, 33, 35
Dimensia
8
Emerson
26, 48, 59, 70, 80, 81, 82
Fisher
36, 37, 44, 45
Funai
80
General Electric
8, 32*, 77, 94*, 101
Goldstar/LG
47
GO VIDEO
71
Hitachi
8, 42, 78
HQ
40
Instant Replay
77, 78
JC Penny
8, 21, 33, 35, 36, 42, 77
JVC
12, 13, 14, 21, 33, 35
Kenwood
21, 33, 35, 47
LXI (Sears)
36, 37, 42, 44, 45, 47, 49, 80
Magnavox
17, 77, 78, 83
Marantz
21, 33, 35
Marta
47
Memorex
37, 77
Minolta
8, 42
* TV/VCR component
Note on IR SETUP codes
Digital program editing is not possible if the VCR does not support IR SETUP codes.
76
, then press the dial.
Brand
IR SETUP code
Mitsubishi/MGA
22, 23, 24, 28, 29
Multitech
23, 32, 80
NEC
21, 33, 35
Olympic
77, 78
Optimus
22
Orion
60
Panasonic
16, 17, 77, 78
Pentax
8, 42
Philco
26, 70, 77, 78
Philips
47, 77, 78, 83
Pioneer
78
Quasar
6, 16, 17, 77, 78
RCA/PROSCAN
7, 8, 16, 40, 41, 42, 77, 78, 78*, 83,
101
Realistic
22, 36, 37, 77, 80, 88
Sansui
21
Singer
73
Samsung
24, 24*, 32, 32*, 41, 94, 94*
Sanyo
26, 36, 37, 47
Scott
22, 23, 24, 28, 32, 37, 40, 41
Sharp
88, 89
Shintom
73
Signature 2000
80, 89
Sylvania
77, 78, 80, 83
Symphonic
80
Tashiro
47
Tatung
21, 33, 35
Teac
21, 33, 35, 80
Technics
77, 78
Toshiba
7, 40, 49
Wards
37, 47, 88, 89, 95
Yamaha
21, 33, 35, 36
Zenith
95
1-18
Dubbing only desired scenes – Digital program editing (on tapes)
MENU
5
For DCR-TRV240:
OTHERS
VIDEO EDIT
DATA CODE
MARK
BEEP
UNDO
COMMANDER
ERASE ALL
DISPLAY
START
VIDEO EDIT
READY
EDIT SET
INDICATOR
RETURN
TOTAL 0:00:00:00
SCENE 0
[MENU] : END
[MENU] : END
For DCR-TRV340:
OTHERS
VIDEO EDIT
DATA CODE
MARK
BEEP
UNDO
COMMANDER
ERASE ALL
DISPLAY
START
VIDEO EDIT
RETURN
EDIT SET
INDICATOR
TAPE
RETURN
MEMORY
TOTAL 0:00:00:00
SCENE 0
[MENU] : END
[MENU] : END
10
VIDEO EDIT
0:08:55:06
EDIT SET
CONTROL
ADJ TEST
"CUT–IN"
"CUT–OUT"
IR SETUP
3
PAUSEMODE
IR TEST
RETURN
[MENU] : END
Dubbing only desired scenes – Digital program editing (on tapes)
(2) Setting the modes to cancel the recording pause on the VCR
1 Turn the SEL/PUSH EXEC dial to select PAUSEMODE, then press the dial.
2 Turn the SEL/PUSH EXEC dial to select the mode to cancel recording pause
on the VCR, then press the dial.
Refer to the operating instructions of your VCR.
VIDEO EDIT
EDIT SET
CONTROL
ADJ TEST
"CUT–IN"
"CUT–OUT"
IR SETUP
PAUSEMODE
PAUSE
IR TEST
REC
RETURN
PB
[MENU] : END
Buttons to cancel recording pause on the VCR
The buttons vary depending on your VCR. To cancel recording pause:
– Select PAUSE if the button to cancel recording pause is X.
– Select REC if the button to cancel recording pause is z.
– Select PB if the button to cancel recording pause is N.
(3) Setting your camcorder and the VCR to face each other
Locate the infrared rays emitter of your camcorder and face it towards the remote
sensor of the VCR.
Set the devices about 30 cm (12 in.) apart, and remove any obstacles between the
devices.
VCR
Remote sensor
A/V connecting cable (supplied)
6
0:08:55:06
VIDEO EDIT
0:08:55:06
1 IN
MARK
UNDO
ERASE ALL
START
EDIT SET
IR
TOTAL 0:00:00:00
SCENE 0
[MENU] : END
7
0:08:55:06
VIDEO EDIT
0:08:55:06
1 IN
EDIT SET
CONTROL
IR
ADJ TEST
i. LINK
"CUT–IN"
"CUT–OUT"
IR SETUP
PAUSEMODE
IR TEST
RETURN
[MENU] : END
75
0:08:55:06
VIDEO EDIT
0:08:55:06
EDIT SET
CONTROL
ADJ TEST
"CUT–IN"
"CUT–OUT"
IR SETUP
PAUSEMODE
PAUSE
IR TEST
RETURN
[MENU] : END
Infrared rays emitter
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv340

Table of Contents