Figure 3: Standard Reflector; Figure 4: One Side Reflector; Figure 5: Two Side Reflectors - Roberts Gorden CoRayVac CRV-B-2 Installation, Operation & Service Manual

Custom-engineered, low-intensity infrared heating systems
Hide thumbs Also See for CoRayVac CRV-B-2:
Table of Contents

Advertisement

CRV-S
I
, O
ERIES
NSTALLATION
PERATION AND
NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, elbows, tees and crosses.
2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from
where the combustion chamber and the tube connect.

FIGURE 3: STANDARD REFLECTOR

A
B
D
C
.

FIGURE 4: ONE SIDE REFLECTOR

A
B
D
C

FIGURE 5: TWO SIDE REFLECTORS

A
B
D
C
6 of 83
S
M
ERVICE
ANUAL
Model
A
CRV-B-2
4
CRV-B-4
4
CRV-B-6
4
CRV-B-8
4
CRV-B-9
4
CRV-B-10
4
CRV-B-12
4
CRV-B-12A
4
Model
A
CRV-B-2
4
CRV-B-4
4
CRV-B-6
4
CRV-B-8
4
CRV-B-9
4
CRV-B-10
4
CRV-B-12
4
CRV-B-12A
4
Model
A
CRV-B-2
4
CRV-B-4
4
CRV-B-6
4
CRV-B-8
4
CRV-B-9
4
CRV-B-10
4
CRV-B-12
4
CRV-B-12A
4
(inches)
B
C
D
20
48
20
20
48
20
20
48
20
20
48
20
36
60
36
36
60
36
36
60
36
36
60
36
(inches)
B
C
D
12
56
20
12
56
20
12
56
20
12
56
20
12
60
42
12
60
42
12
60
42
12
60
42
(inches)
B
C
D
12
56
12
12
56
12
12
56
12
12
56
12
12
60
12
12
60
12
12
60
12
12
60
12
(centimeters)
A
B
C
11
51
122
11
51
122
11
51
122
11
51
122
11
92
153
11
92
153
11
92
153
11
92
153
(centimeters)
A
B
C
11
31
143
11
31
143
11
31
143
11
31
143
11
31
153
107
11
31
153
107
11
31
153
107
11
31
153
107
(centimeters)
A
B
C
11
31
143
11
31
143
11
31
143
11
31
143
11
31
153
11
31
153
11
31
153
11
31
153
D
51
51
51
51
92
92
92
92
D
51
51
51
51
D
31
31
31
31
31
31
31
31