Clearance Data; Figure 1: Standard Reflector; Figure 2: One Side Reflector; Figure 3: Two Side Reflectors - Roberts Gorden CRT-10 Installation, Operation & Service Manual

Corayvac series custom-engineered, low-intensity infrared heating systems
Table of Contents

Advertisement

3.2 Clearance Data

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, tees, elbows and
crosses.
2. Clearances B, C and D can be reduced by 50% after 7.5 m (25') of tubing
downstream from where the burner and burner tube connect.
3. All measurements are in Millimeters.
CLEARANCES TO COMBUSTIBLES

Figure 1: STANDARD REFLECTOR

Figure 2: ONE SIDE REFLECTOR

Figure 3: TWO SIDE REFLECTORS

Model
A
B
CRT-10
150
510
CRT-15
150
510
CRT-20
150
510
CRT-25
150
920
CRT-30
150
920
Model
A
B
CRT-10
150
305
CRT-15
150
305
CRT-20
150
305
CRT-25
150
305
CRT-30
150
305
Model
A
B
CRT-10
150
305
CRT-15
150
305
CRT-20
150
305
CRT-25
150
305
CRT-30
150
305
SECTION 3: C
C
RITICAL
ONSIDERATIONS
C
D
1220
510
1220
510
1220
510
1530
920
1530
920
|
C
D
1430
510
1430
510
1430
510
1530
1070
1530
1070
C
D
1430
305
1430
305
1430
305
1530
305
1530
305
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crt-15Crt-30Crt-20Crt-25

Table of Contents