External Trigger Signals And Timing Of Shooting - Sony XCG-H280E Technical Manual

Digital video camera module
Hide thumbs Also See for XCG-H280E:
Table of Contents

Advertisement

Analog Control
• Gain
• BlackLevel
• BlackLevelAdjust
LUT Control
• LUTEnable
• LUTFormat
• BinarizationThreshold
UserSet Control
• UserMemoryValue
When using Bulk or Sequential trigger mode, note that
the following settings are ignored and have no effect:
Image Format Control
• SensorTaps
• Width
• Height
• BinningHorizontal
• BinningVertical
• PixelFormat
• TestImageSelector
• GainAutoAreaHighlight
• BalanceWhiteAutoHighlight
Acquisition Control
• AcquisitionFrameRate
• AcquisitionFrameRateAuto
• TriggerMode
• TriggerSource
• TriggerInhibit
• TriggerActivation
• TriggerShift
• TriggerControl
• TriggerDelay
• ExposureMode
• ExposureAuto
Analog Control
• GainAuto
• BlackLevelAutoBalance
External Trigger Signals and
Timing of Shooting
In Trigger Edge mode, the time from when detecting a
trigger signal to when starting exposure is 1.5 usec.
Shooting is performed according to the "Exposure
Time" specified in advance.
In Trigger Width mode, "Minimum Delay" operation or
"Exact Exposure Time" operation can be selected. The
relationship between the time till starting exposure and
the exposure time are shown in the table below.
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * aegis-g2@aegiselect.com * http://www.aegis-elec.com
Trigger
Trigger
mode
Control
Trigger Edge
Minimum
Delay
Trigger Width Minimum
Delay
Exact
Exposure
Time
Trigger Edge
1.5usec
Trigger signal
Exposure
Sensor output
Trigger Width/Minimum Delay mode
Setting parameter: TriggerControl = MinimumDelay
a
Trigger signal
1.5
a+33usec
usec
Exposure
Sensor output
Trigger Width/Exact Exposure Time mode
Setting parameter:TriggerControl =ExactExposureTime
a
Trigger signal
35usec
Exposure
Sensor output
Note
When Trigger Shift is active, Trigger Width/Exact Time
Exposure mode cannot be selected.
Time till
Duration of
starting
exposure
exposure
1.5 usec
Exposure
Time
1.5 usec
Valid period
of Trigger
Width+33
usec
35 usec
Valid period
of Trigger
Width
a
13