Exposure Time - Sony XCG-H280E Technical Manual

Digital video camera module
Hide thumbs Also See for XCG-H280E:
Table of Contents

Advertisement

Setting parameters:GainSelector = DigitalGreenAll
Notes
• When using pixel gain, the output level interval may
not be continuous. This phenomenon occurs when
there is not video output signal that corresponds to the
output step. This is not a malfunction.
• If pixel gain is set to high, noise may be apparent. This
is not a malfunction.
• When specifying the upper or lower limit of the
exposure time, be sure to observe the following
requirements.
BalanceWhiteAutoAreaWidth +
BalanceWhiteAutoAreaOffsetX
BalanceWhiteAutoAreaHeight +
BalanceWhiteAutoAreaOffsetY
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * aegis-g2@aegiselect.com * http://www.aegis-elec.com
18
Gain[DigitalGreenAll] = 3 (dB)
BalanceWhiteAuto = Once
100
100

Exposure Time

The camera provides both manual and automatic
exposure control capabilities.
Manual exposure control
Exposure for the specified time is achieved by internal
continuous driving or Trigger Edge operation.
Setting parameter: ExposureTime = 10 to 2,000,000 (us)
Auto exposure control
The camera provides the auto exposure control function
to automatically control exposure time according to a
common user-specified detection frame and image
average level sharing with auto gain control function.
The upper and lower limits of the variable range are
adjustable.
If the auto exposure control is set to "Once," it
automatically changes to "Off" when the exposure time
reaches the image average level or the upper or lower
limit of the variable range. With the "Continuous"
setting, auto exposure control constantly operates.
When both auto exposure control and auto gain control
are activated, gain is lowered and exposure time is
extended within the variable range.
Setting parameters:ExposureAuto = Off/Once/
Continuous
ExposureAutoSpeed = 1 to 256
ExposureAutoLowerLimit = 10 to
2,000,000 (us)
ExposureAutoUpperLimit = 10 to
2,000,000 (us)
Note
Neither the upper nor lower limits of the exposure time
variable range affect the configurable range of exposure
time setting by manual exposure control.
When specifying the upper or lower limit of the
exposure time, be sure to observe the following
requirements.
ExposureAutoLowerLimit < ExposureAutoUpperLimit