Airflow Direction - Panasonic CS-E24DKE Service Manual

Table of Contents

Advertisement

Basic Rotation Speed
8.1.9.

Airflow Direction

1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote control).
Vertical Airflow
Operation Mode
Heating
Cooling, Soft Dry and Fan, Ion
Mode Judgment in Auto
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1
below. When the air conditioner is stopped using remote control, the vane will shift to close position.
Airflow Direction
Auto with Heat Exchanger
Temperature
Manual
Auto
Manual
Auto
Manual
23
Vane Angle (°)
1
2
3
A
19
B
49
C
8
D
8
8
17
33
8 ~ 38
8
17
25
8
8
17
25
CS-E24DKE CU-E24DKE
4
5
49
60
33
38
33
38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-e24dke

Table of Contents