Panasonic CS-E24DKE Service Manual page 60

Table of Contents

Advertisement

CS-E24DKE CU-E24DKE
Attached accessories
Applicable piping kit
CZ-52F5, 7, 10BP (E24DK)
Select the best location
INDOOR UNIT
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
• Recommended installation height for indoor unit
shall be at least 2.5 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
• There should not be any animal or plant which could
be affected by hot air discharged.
• Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
• Do not place any obstacles which may cause a short
circuit of the discharged air.
• If piping length is over 7.5 m, additional refrigerant
should be added as shown in the table.
Indoor/Outdoor Unit Installation Diagram
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
60