Compressor Operation Frequency; Cooling Operation; Thermostat Control - Panasonic CS-E24DKE Service Manual

Table of Contents

Advertisement

CS-E24DKE CU-E24DKE
8.1.2.

Compressor Operation Frequency

Intake Air Temperature - Internal Setting Temperature (°C)
Zone
Cooling
1
-2.0
2
-1.5
3
-1.0
4
-0.5
5
0.0
6
0.5
7
1.0
8
1.5
9
2.0
10
2.5
11
Nil
12
Nil
Operating Frequency Calculation Formula:
CompHz = Freq. A × Freq. H + Freq. C
Example Calculation:
Model No.: E24DK
Operation Mode: Cooling
When Intake Air Temperature - Internal setting Temperature:
1.5°C
CompHz
=
Freq. A × Freq. H + Freq. C
=
1.8 × 30 + 13.0
=
67 Hz (Decimal point is ignored)
Remarks:
When Freq. H is equal to 30 (Cooling), 35 (Heating) or above, the Comp. may run at the freq. higher than Fc or Fh up to max.
freq. operation.
Best Amenity Control
Every 90s (Cooling), 120s (Heating) maintain same zone Freq. H + 1 until Fc, Fh.
8.1.3.

Cooling Operation

8.1.3.1.

Thermostat control

• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point +0.5°C.
Soft Dry
Heating
-3.0
1.0
-2.5
0.5
-2.0
0.0
-1.5
-0.5
-1.0
-1.0
-0.5
-1.5
0.0
-2.0
0.5
-2.5
1.0
-3.0
1.5
-3.5
Nil
-4.0
Nil
-4.5
16
Cooling
Soft Dry
1
5
11
10
15
12
18
14
22
16
25
18
28
21
30
24
30
27
30
30
Nil
Nil
Nil
Nil
Cooling & Soft Dry
Low Load (Freq. H
13)
High Load (Freq. H > 13)
Heating
Low Load (Freq. H
15)
High Load (Freq. H > 15)
Freq. Range
Cooling
Fc
Operation Range
Heating
Fh
Operation Range
Freq. H
Heating
Remark
3
13
17
21
26
32
35
Fh
35
Fc, Fh
35
Fc, Fh
35
Fc, Fh
35
Fh
35
Fh
E24DK
Freq. A
Freq. C
2.0
10.0
1.8
13.0
E24DK
Freq. A
Freq. C
1.5
11.0
1.7
8.0
E24DK
64
14 ~ 74
68
14 ~ 100