Indoor Fan Motor Operation - Panasonic CS-E24DKE Service Manual

Table of Contents

Advertisement

CS-E24DKE CU-E24DKE
Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on
the above operation mode chart, every 30 minutes.
Remote Control Setting Temperature (°C)
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice
verse.
Operation Mode change from
Cooling/Soft Dry → Heating
Heating → Cooling/Soft Dry
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 + 6 = 31; T3 = 25 - 7 = 18
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
8.1.7.

Indoor Fan Motor Operation

A. Basic Rotation Speed (rpm)
• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
Tab (rpm)
E24DK
[Heating]
Remote Control
Tab (rpm)
E24DK
16 ~ 18
19 ~ 22
23 ~ 26
27 ~ 30
O
O
SHI
Hi
Me+
1670
1580
1480
O
O
SSHI
SHi
Me+
1690
1690
1590
T1
+10
+8
+7
+6
Temperature shifts (°C)
O
O
O
Me
Me-
Lo
1390
1290
1200
O
O
O
Me
Me-
Lo
1500
1400
1310
18
T2
T3
+8
-5
+7
-7
+6
-7
+5
-8
-2
+2
Lo-
SLo
930
840
Lo-
SLo
930
400
SSLo
630
SSLo
300